Published 15 November 2026 at 06:29
It is Tuesday afternoon and the auditor asks how quickly the cooked batch was cooled down last night. The answer is on a piece of paper with three handwritten values, and between two of them there were four hours without any check. It is a common situation in kitchens, production lines and pharmaceutical storage: the temperature was measured, but not often enough, and not in the product.
What it is
The stainless steel ETI ThermaData is a standalone temperature logger with a Ø3.3 x 50 mm penetration probe. The housing is food-grade 316 steel with IP66/67 protection, so it withstands moisture, impacts and cleaning better than a plastic logger. The measuring range is -20 to +125 °C with a resolution of 0.1 °C and an accuracy of ±0.5 °C. The memory holds 16,000 readings.
What problems it solves
The logger measures automatically at an interval you choose, from 1 second to 255 minutes, so you avoid gaps between manual checks. With the ThermaData Hub software you set the clock, delayed start and upper and lower alarm limits. When you connect the USB-C cable, the data is downloaded and a PDF summary is created automatically. The measurement series thus becomes a document, not a scrap of paper.
When and why it is used
It is suited to situations where the temperature profile is what needs to be proven, not just a single value. The probe is inserted into the product, so you measure the temperature where it matters and not in the surrounding air. This makes it well suited as a basis for HACCP self-monitoring.
Three use cases
Food production: You place the logger in a cooked batch and follow the cooling from core temperature to cold room temperature. The curve shows whether the time limits were met, even during the night.
Pharmaceuticals and laboratory: For processes or storage where the temperature rises towards 125 °C, the logger provides a traceable curve. If needed, a UKAS 3-point certificate can be ordered at an extra cost, which makes audits easier.
Cold and frozen storage: Placed in a large refrigerator or freezer, the logger shows how the temperature varies over the course of the day, for example after goods are received or during defrosting. The alarm limits make deviations clear afterwards.
The economics
Manual logging costs working time every day, and it still gives sparse data. A logger removes that routine and reduces the risk of an entire batch being discarded because the documentation does not hold up. With a single deviation that you can show was harmless, or an audit that goes smoothly, the instrument has generally paid for itself. In addition, the same logger can be used over and over again.
If you want to replace handwritten lists with measurement data you can stand behind, the stainless steel ThermaData is available from us: see the product here.