Published 29 November 2026 at 19:38
The boiler shows 65 degrees and the circulation is running, but in the shower at the far end of the floor the water never gets warmer than 40. Anyone who has carried out a self-inspection of a water system will recognize the situation. The temperature at the water heater says very little about what is happening at the tap, and it is at the taps and in the dead pipe branches that Legionella bacteria thrive, especially between about 20 and 45 °C.
What the kit contains
The kit is built around the Therma 1 digital thermometer with a type K thermocouple. The measuring range is -99.9 to 299.9 °C with a resolution of 0.1 °C, and the instrument’s accuracy is ±0.4 °C ±0.1 % of reading. A max/min function is included. The case holds three probes: an immersion probe for water samples, a surface probe for pipe straps, and a PTFE wire probe. A countdown timer, 100 probe wipes and an ABS carry case are also included. The housing has Biomaster protection and the instrument is delivered with a free traceable calibration certificate.
What problems it solves
Legionella control is about comparable measurement values. If one technician measures after ten seconds of running time and the next after two minutes, the measurement series cannot be compared. The timer ensures that every measuring point gets the same running time. Three probes mean you don’t have to improvise: the water is measured with the immersion probe, pipes are measured from the outside with the surface probe without opening the system, and the wire probe reaches tight spots that a rigid probe cannot get to. The wipes let you clean the probe between measuring points, which is sensible when you move from tap to tap.
Three use cases
Property management: On the routine round you measure hot and cold water at selected taps and compare with the guideline values, for example at least 50 °C hot water at the tap and cold water below 20 °C. The max/min value shows whether the temperature actually stabilizes.
Plumbing installation and balancing: After a renovation you need to show that the circulation works. The surface probe on the return pipe shows how much the temperature drops along the loop, without you having to drain anything.
Care facilities, hotels and sports facilities: These have many showers and rarely used taps. With a fixed measuring routine and a calibrated instrument, the results can be entered into the self-inspection records and presented during inspections.
Why it pays off
A measurement log based on an uncalibrated instrument carries little weight in an audit. The certificate makes the measurement values traceable, and a battery that according to the specification lasts at least five years means the instrument is seldom unusable when you need it. The cost of a single sampling with laboratory analysis and corrective actions after a deviating result quickly exceeds the price of the kit, and regular temperature measurement often reveals the problem before the bacterial sample does.
If you want to see the full contents and the specification, the kit is described on the product page.