Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Chlorine level doesn’t tell the whole story: pH and ORP show whether disinfection actually worksWith a one-second reading, you can check every batch, not just the sampleTwelve measurement points at once show where the oven temperature really deviatesThe Core Temperature Thermometer That Withstands the Dishwasher Environment and the Auditor’s QuestionsHow to tell in ten seconds whether your AdBlue tank contains 32.5 percent urea or mostly waterMeasure What You See: How Automatic Magnification Reading Delivers Reliable Measurements Right on the ScreenMeasure the scratch, solder joint or wear right at the machine instead of sending the part to the labThe Humidity Problem No One Noticed Until the Sensor Ended Up Where It Actually OccurredThe Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Chlorine level doesn’t tell the whole story: pH and ORP show whether disinfection actually worksWith a one-second reading, you can check every batch, not just the sampleTwelve measurement points at once show where the oven temperature really deviatesThe Core Temperature Thermometer That Withstands the Dishwasher Environment and the Auditor’s QuestionsHow to tell in ten seconds whether your AdBlue tank contains 32.5 percent urea or mostly waterMeasure What You See: How Automatic Magnification Reading Delivers Reliable Measurements Right on the ScreenMeasure the scratch, solder joint or wear right at the machine instead of sending the part to the labThe Humidity Problem No One Noticed Until the Sensor Ended Up Where It Actually OccurredThe Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visible
Item number 56-MCR-4TC

TandD 4-channel logger for thermocouples (types K, J, T, S, R, N, E). Measuring range -200 to +1760 °C depending on probe type. Modular — can be combined to 16 channels

4.375 SEK

In stock

TandD 4-channel logger for thermocouples (types K, J, T, S, R, N, E). Measuring range -200 to +1760 °C depending on probe type. Modular — can be combined to 16 channels

Request a quote 56-MCR-4TC

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category: , , , ,

Other models in the series 6

Description

The 56-MCR-4TC is TandD’s 4-channel industrial thermocouple logger featuring a built-in touch panel, SD card storage, and galvanically isolated inputs. For larger installations, up to 4 units can be linked (16 channels total), which are synchronized via a common start and share settings.

Supports thermocouples K, J, T, S, R — covering temperatures from -199 to +1760 °C. The galvanic isolation between channels allows you to measure signals with different potential levels without crosstalk. Massive memory: up to 480,000 data points at 1 channel or 120,000 at 4 channels — this is a logger designed for long industrial processes.

NOTE: Thermocouples are NOT included — connect your own. Also available: 56-MCR-4V for voltage measurement (±50 V).

Thermocouple Compatibility

  • Type K — -199 to +1370 °C (industrial standard)
  • Type J — -199 to +1200 °C
  • Type T — -199 to +400 °C (cryogenic)
  • Type S — -50 to +1760 °C (PtRh10-Pt)
  • Type R — -50 to +1760 °C (PtRh13-Pt)

Features

  • 4 channels thermocouple with galvanic isolation
  • Measurement range -199 to +1760 °C (sensor-dependent)
  • Accuracy K/J/T: ±(0.5 + 0.003 × t) °C at ≥-100 °C; S/R: ±(1.5 + 0.003 × t) °C at ≥100 °C
  • Cold Junction compensation ±0.5 °C (10–40 °C operating range)
  • Resolution 0.1 °C
  • Groupable — up to 4 units = 16 synchronized channels
  • Massive memory: up to 480,000 / 240,000 / 160,000 / 120,000 measurements (1/2/3/4 channels)
  • SD card storage (SD/SDHC) — automatic export when internal memory is full = no data loss
  • Built-in touch panel for easy setup + trend graph display
  • Preheating function saves battery life
  • Logging interval from 100 ms to 60 min
  • Powered by 2 × AA batteries or AC adapter or USB bus

Specification

Measurement channels Temperature 4 channels — thermocouple K/J/T/S/R via screw terminals, galvanically isolated
Measurement range -199 to +1760 °C (sensor dependent)
Cold Junction compensation ±0.5 °C (10–40 °C operation), ±0.8 °C (other)
Resolution 0.1 °C
Input method Scanning, differential input, channel isolated
Logging capacity 480,000 (1 ch) / 240,000 (2 ch) / 160,000 (3 ch) / 120,000 (4 ch) measurements
Logging interval 100, 200, 500 ms / 1, 2, 5, 10, 15, 20, 30 sec / 1, 2, 5, 10, 15, 20, 30, 60 min
Group function Up to 4 units (16 channels) synchronized
Display Built-in LCD with touch panel — displays measurements, trend graph, status
Communication USB 2.0 Mini-B
External memory SD / SDHC card (manual or automatic export)
Power supply 2 × AA alkaline LR6, 2 × AA Ni-MH, AC adapter 56-AD-05A2/C2, USB bus 5V 250 mA
Battery life approx. 4.5 to 130 days (4 channels, instant value, AA alkaline)

Included

  • 56-MCR-4TC logger with touch panel
  • 2 × AA alkaline batteries
  • USB Mini-B cable 56-US-15C
  • Manual set with warranty certificate
  • NOTE: thermocouples NOT included — ordered separately
  • NOTE: SD card NOT included

Applications

The 56-MCR-4TC is selected for industrial temperature measurement using thermocouples: heat treatment furnaces, glass and metal industries, plastic recycling, heat-retaining processes, autoclaves, and calibration tasks requiring multiple thermocouples simultaneously. The group function (16 channels) makes it suitable for temperature mapping of large furnaces/chambers. For voltage measurement instead, see 56-MCR-4V. For a simpler 2-channel thermocouple model with WiFi, see 56-TR75A2.