Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Chlorine level doesn’t tell the whole story: pH and ORP show whether disinfection actually worksWith a one-second reading, you can check every batch, not just the sampleTwelve measurement points at once show where the oven temperature really deviatesThe Core Temperature Thermometer That Withstands the Dishwasher Environment and the Auditor’s QuestionsHow to tell in ten seconds whether your AdBlue tank contains 32.5 percent urea or mostly waterMeasure What You See: How Automatic Magnification Reading Delivers Reliable Measurements Right on the ScreenMeasure the scratch, solder joint or wear right at the machine instead of sending the part to the labThe Humidity Problem No One Noticed Until the Sensor Ended Up Where It Actually OccurredThe Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Chlorine level doesn’t tell the whole story: pH and ORP show whether disinfection actually worksWith a one-second reading, you can check every batch, not just the sampleTwelve measurement points at once show where the oven temperature really deviatesThe Core Temperature Thermometer That Withstands the Dishwasher Environment and the Auditor’s QuestionsHow to tell in ten seconds whether your AdBlue tank contains 32.5 percent urea or mostly waterMeasure What You See: How Automatic Magnification Reading Delivers Reliable Measurements Right on the ScreenMeasure the scratch, solder joint or wear right at the machine instead of sending the part to the labThe Humidity Problem No One Noticed Until the Sensor Ended Up Where It Actually OccurredThe Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visible
Item number 17-137301

ETI Sensor, thermocouple type T, air and gas probe without cable, Ø3.3 x 120 mm

426 SEK

In stock

Plug-mounted air/gas temperature probe 

Response time less than one second
Probe temperature range -75 to 250 °C
Accuracy (Type K) ±0.5 °C (0–100 °C)
Accuracy (Type T) ±0.2 °C (-20–70 °C)
Probe dimensions Ø3.3 x 120 mm
Designed for use with the 17-323950 probe handle

Request a quote 17-137301

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Description

Air or gas thermocouple temperature probe. This plug-mounted air/gas temperature probe features a perforated stainless steel tip for fast response and is ideal for measuring temperatures in refrigerators, chillers, freezers, and the HVAC air conditioning and heating sectors.
Designed to extend the temperature measuring capabilities of your ETI thermometer when used in conjunction with the interchangeable probe handle, the probe has a response time of less than one second. Temperature range -75 to 250 °C. Maximum tip temperature 250 °C. Probe dimensions Ø3.3 x 120 mm

Specifications

Probe measuring range: -75 to 250 °C
Probe accuracy: ±0.5 °C, 0 °C to 100 °C
Probe response time: Less than 1 second
Probe diameter: 3.3 mm