Published 26 November 2026 at 13:08
The oven shows 180 °C on its own display, but the products are still treated unevenly. Someone has measured at one spot with a handheld thermometer and approved the result. The problem is that a single measurement point says little about how the temperature is distributed across the space or over time, and the deviation only becomes apparent when the customer files a complaint.
What it is
This is a temperature data logger with 12 channels for thermocouples of types J, K, E, T, R and S. You can display channels 1 to 8 or 9 to 12 at the same time on the screen. The measured values are saved with a date and time stamp in a format that can be opened directly in Excel. A 2 GB SD card holds up to 20 million readings, and you set the sampling rate between 1 and 3600 seconds. The delivery includes 12 type K wire probes, an SD card, eight AA batteries and a hard case.
What problems it solves
You see all measurement points at the same time, so a hot or cold zone shows up immediately. The offset adjustment lets you zero the readings or measure relative to a reference, which is useful when comparing points against each other. Min/max and data hold capture peaks that would otherwise disappear between two manual readings. And since the logger runs on its own, you don’t have to stand at the machine writing down values.
When and why it is used
You use it when a single value is not enough: for mapping, troubleshooting and validation. In those cases you need both the spread between points and the progression over hours or days.
Three areas of use
Manufacturing industry: Place probes at several locations in a hardening furnace or drying oven and check that the temperature is even across the entire load. The same setup works on a mold where the cooling should be uniform in all zones.
Food production: In a refrigerated cabinet or heating cabinet, you can log the temperature throughout an entire production cycle and show that the limit values have been maintained. The data from the SD card can be added directly to your self-inspection documentation.
Installation and maintenance: Mount wire probes on pipes in a hot water system and follow how the temperature drops in different branches during the night. This provides actual data when Legionella risk is suspected or when balancing the circulation.
Why it pays off
The cost of an uneven process is seldom the measurement itself. It is scrap, rework and time spent guessing. With twelve probes in one run, you often get the answer in a day instead of several rounds of single-point measurements. The documentation is also saved automatically, which reduces manual administration and makes audits easier. An instrument case with ready-to-use probes means the logger can be moved between machines without preparation.
If you need data to understand a temperature process, rather than a single figure, a multi-channel logger is the right tool.