Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsStale air in the meeting room is a measurable number, and the dew point decides whether a surface stays glossy or turns mistyMicroscope with 108 mm to the object: how to measure on the part without having to move itVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsStale air in the meeting room is a measurable number, and the dew point decides whether a surface stays glossy or turns mistyMicroscope with 108 mm to the object: how to measure on the part without having to move it
Item number 53-VFM200

VOC and Formaldehyde Meter

4.163 SEK

In stock

Measures volatile organic compounds and CH2O/HCHO concentrations in real time

Request a quote 53-VFM200

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Description

The VFM200 measures VOC (Volatile Organic Compound) and formaldehyde concentrations in real time. It features a fast response time, a compact design, and portability, making it ideal for monitoring indoor air quality in homes, offices, industrial facilities, hotels, schools, and other indoor environments. Potential sources of VOCs include paints, coatings, adhesives, cigarette smoke, pesticides, hygiene products, vehicle exhaust, new furniture, wallpaper, household cleaning agents, cooking, and fuels. Detected chemicals include: Acetone, Ethylene Glycol, Formaldehyde, Xylene, 1,3-Butadiene, Tetrachloroethylene, Hydrogen Sulfide, Ammonia, Toluene, Benzene, Methylene Chloride, Perchloroethylene, and MTBE.

Features

  • Backlit LCD display showing TVOC (Total Volatile Organic Compound) and HCHO (Formaldehyde) concentrations simultaneously in real time
  • Fast response and high accuracy; the formaldehyde sensor is a fuel cell
  • Two selectable units (ppm, mg/m³)
  • Adjustable audible and visual alarm for high/low values
  • Automatic power-off
  • Includes rechargeable battery and AC adapter/charger (multi-plug for USA, EU, UK, and AU)
Specification

The VFM200 measures VOC (Volatile Organic Compound) and formaldehyde concentrations in real time. It features a fast response time, a compact design, and portability, making it ideal for monitoring indoor air quality in homes, offices, industrial facilities, hotels, schools, and other indoor environments. Potential sources of VOCs include paints, coatings, adhesives, cigarette smoke, pesticides, hygiene products, vehicle exhaust, new furniture, wallpaper, household cleaning agents, cooking, and fuels. Detected chemicals include: Acetone, Ethylene Glycol, Formaldehyde, Xylene, 1,3-Butadiene, Tetrachloroethylene, Hydrogen Sulfide, Ammonia, Toluene, Benzene, Methylene Chloride, Perchloroethylene, and MTBE.

Features

  • Backlit LCD display showing TVOC (Total Volatile Organic Compound) and HCHO (Formaldehyde) concentrations simultaneously in real time
  • Fast response and high accuracy; the formaldehyde sensor is a fuel cell
  • Two selectable units (ppm, mg/m³)
  • Adjustable audible and visual alarm for high/low values
  • Automatic power-off
  • Includes rechargeable battery and AC adapter/charger (multi-plug for USA, EU, UK, and AU)
PDF (2)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *