Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsStale air in the meeting room is a measurable number, and the dew point decides whether a surface stays glossy or turns mistyMicroscope with 108 mm to the object: how to measure on the part without having to move itVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsStale air in the meeting room is a measurable number, and the dew point decides whether a surface stays glossy or turns mistyMicroscope with 108 mm to the object: how to measure on the part without having to move it
Item number 53-PRC30

Multifunctional Process Calibrator

9.775 SEK

In stock

Precision Current & Voltage & Temperature Source / Measurement Calibrator

Request a quote 53-PRC30

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Description
  • 0 to 24mA (-25 to 125%) reading
  • 24V DC power supply for 2-wire current loop
  • 0 to 20V DC calibration source
  • Can measure/calibrate up to 8 types of thermocouples (J, K, T, E, C, R, S and N)
  • CJC – Cold junction compensation
  • Up to five user-definable calibration presets
  • Handheld with rugged instrument housing and large dot-matrix digital backlit LCD
  • High accuracy. The calibration function simulates precision thermocouple outputs for use in calibrating thermometers, transmitters, control units, or recorders
  • Output is displayed in terms of millivolts or temperature based on thermocouple tables
  • Zero adjustment, automatic zero when powered on, and change mode
  • Standard banana I/O ports and mini thermocouple connector
  • Large battery pack for extended duty cycle
  • External AC adapter for continuous duty cycle
  • Complete with test leads, alligator clips, calibration cables, 100V-240V AC universal adapter with 4 plugs, six AA batteries, and hard case
Specification
  • 0 to 24mA (-25 to 125%) reading
  • 24V DC power supply for 2-wire current loop
  • 0 to 20V DC calibration source
  • Can measure/calibrate up to 8 types of thermocouples (J, K, T, E, C, R, S and N)
  • CJC – Cold junction compensation
  • Up to five user-definable calibration presets
  • Handheld with rugged instrument housing and large dot-matrix digital backlit LCD
  • High accuracy. The calibration function simulates precision thermocouple outputs for use in calibrating thermometers, transmitters, control units, or recorders
  • Output is displayed in terms of millivolts or temperature based on thermocouple tables
  • Zero adjustment, automatic zero when powered on, and change mode
  • Standard banana I/O ports and mini thermocouple connector
  • Large battery pack for extended duty cycle
  • External AC adapter for continuous duty cycle
  • Complete with test leads, alligator clips, calibration cables, 100V-240V AC universal adapter with 4 plugs, six AA batteries, and hard case