Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%With a one-second reading, you can check every batch, not just the sampleTwelve measurement points at once show where the oven temperature really deviatesThe Core Temperature Thermometer That Withstands the Dishwasher Environment and the Auditor’s QuestionsHow to tell in ten seconds whether your AdBlue tank contains 32.5 percent urea or mostly waterMeasure What You See: How Automatic Magnification Reading Delivers Reliable Measurements Right on the ScreenMeasure the scratch, solder joint or wear right at the machine instead of sending the part to the labThe Humidity Problem No One Noticed Until the Sensor Ended Up Where It Actually OccurredThe Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleGhost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%With a one-second reading, you can check every batch, not just the sampleTwelve measurement points at once show where the oven temperature really deviatesThe Core Temperature Thermometer That Withstands the Dishwasher Environment and the Auditor’s QuestionsHow to tell in ten seconds whether your AdBlue tank contains 32.5 percent urea or mostly waterMeasure What You See: How Automatic Magnification Reading Delivers Reliable Measurements Right on the ScreenMeasure the scratch, solder joint or wear right at the machine instead of sending the part to the labThe Humidity Problem No One Noticed Until the Sensor Ended Up Where It Actually OccurredThe Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleGhost voltage that disappears when the meter loads the circuit: how to tell real voltage from false
Item number 17-800890

ETI Test Strips for Frying Oils, Easily Check the Quality of the Oil You Use in Fryers

540 SEK

In stock

Test strips for frying oil – to test the quality of the frying oil

Affordable, no sample preparation or special training required
Use in cold oil below 40 °C
Simple dip-and-read method
Easy-to-read color chart for decision-making
Contains 100 test strips

Request a quote 17-800890

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Other models in the series 16

Description

These test strips for frying oil quality help you maintain the quality of your fried food, while also helping to save money by preventing the premature disposal of cooking oil.
The test strips work equally well in animal, vegetable, and A/V blended frying oil (abbreviation). They are sold in storage bottles containing 100 oil quality test strips, which include an easy-to-read color chart.
To test your frying oil, hold the test strip by the long white end and dip the test strip into the oil (maximum oil temperature 40 °C) so that the entire colored band is submerged. Keep the test strip in the oil for 2 seconds, then remove it and wait 2 minutes, then compare the strip with the color chart.
It is recommended that the frying oil test be performed at the beginning of each shift/working day before the user begins to apply heat to the oil.
To ensure accuracy, the test strips should not be stored in humid conditions or in an area where they may be exposed to water or oil before use.
ETI test strips are designed to measure FFA (free fatty acids), which is a carboxylic acid with a long chain. The more free fatty acids present in the oil, the higher the acid value (AV). Acid value is the number of milligrams of potassium hydroxide (KOH) required to neutralize the fatty acids in 1 gram of oil sample. By dipping the reagent end of the test strip for 2 seconds, the oil is absorbed and the fatty acids in the oil react with the potassium hydroxide in the reagent.
After 2 minutes, the color-developing chemical compound in the reagent changes depending on the mg/KOH/g required to neutralize the FFA in the oil. This color can then be matched with the color chart on the back of the bottle. 0-0.5 is IDEAL, 1.5-2.5 is CAUTION, and 3.0-5.0 is POOR.
Free fatty acids are not suitable for identifying the age of the fat, regardless of whether they are present in the oil or not.

Additional information
Product Type

Givar-tillbehör

PDF (2)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *