Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Measure the scratch, solder joint or wear right at the machine instead of sending the part to the labThe Humidity Problem No One Noticed Until the Sensor Ended Up Where It Actually OccurredThe Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleGhost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseThree seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Measure the scratch, solder joint or wear right at the machine instead of sending the part to the labThe Humidity Problem No One Noticed Until the Sensor Ended Up Where It Actually OccurredThe Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleGhost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseThree seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to change

Schut universal sine vise 0-45°, jaw opening 60 mm: How a 100 mm sine bar and a 34.20 mm gauge block stack produce a 20° angle with 0.001° accuracy

Published July 7, 2026 at 15:17

Angle fixturing of workpieces for grinding, milling, inspection or drilling is one of the fundamental challenges of workshop metrology. Direct angle measurement with a protractor typically gives 1° resolution, which is insufficient for modern production tolerances. A digital angle gauge reaches 0.05° resolution but does not fix the workpiece. The optimal solution — and the standard that workshop metrology has used for over 100 years — is the sine bar vice, which converts angle fixturing into a linear height measurement where gauge blocks become the decisive accuracy factor.

What the Schut sine bar vice is

Universal sine bar vice, hardened (art. 909.748) from Schut ECONOMY LINE is a precision sine bar vice for workshop use. The instrument:

  • Has an angle range of 0-45° (upward).
  • Has hardened, ground reference surfaces and two cylindrical sine reference rollers.
  • Has a jaw opening of 60 mm, jaw width of 50 mm, jaw depth of 25 mm.
  • Total length 140 mm.
  • Has a 360° rotatable base — can be positioned for both tilt and rotation.
  • Works in combination with standard gauge blocks (Schut or equivalent DIN 861 set).
  • Is compatible with ISO 17025 calibration certificates.

Key specifications:

  • Manufacturer: Schut (Germany)
  • Series: ECONOMY LINE
  • Type: Universal sine bar vice
  • Angle range: 0-45°
  • Base rotation: 360°
  • Jaw opening: 60 mm
  • Jaw width: 50 mm
  • Jaw depth: 25 mm
  • Total length: 140 mm
  • Material: Hardened steel (typically HRC 60+)
  • Sine base: 100 mm between centers of the sine rollers
  • Article number: 64-909748

Schut universal sine bar vice 60 mm jaw opening, 140 mm length

Sine principle and trigonometry

The sine bar vice consists of a fixed flat base and an upper plate (with the vice mounted on it) that is hinged at one end. Under the other end rests a cylindrical sine roller, which sits on a gauge block stack. The configuration forms a right triangle:

  • The hypotenuse is the distance between the sine rollers (base length L, typically 100 mm).
  • The opposite side is the height of the gauge block stack H.
  • The angle α is the angle at which the upper plate tilts from horizontal.

Trigonometrically: sin(α) = H / L → H = L × sin(α)

Practical examples with L = 100 mm:

  • 1°: H = 100 × sin(1°) = 1.7452 mm
  • 5°: H = 100 × sin(5°) = 8.7156 mm
  • 10°: H = 100 × sin(10°) = 17.3648 mm
  • 20°: H = 100 × sin(20°) = 34.2020 mm
  • 30°: H = 100 × sin(30°) = 50.0000 mm
  • 45°: H = 100 × sin(45°) = 70.7107 mm

The operator builds a gauge block stack that precisely matches the height H for the desired angle, places the stack under the sine roller, and sets the upper plate on it. The angle then becomes exactly α — within the accuracy of the gauge blocks.

Gauge block accuracy → angle accuracy

Gauge blocks according to DIN 861 are available in several precision classes:

  • Class 0: Reference standard, ±0.05-0.15 µm tolerance (for lengths of 25 mm).
  • Class 1: Calibration lab, ±0.1-0.3 µm.
  • Class 2: Workshop reference, ±0.2-0.5 µm.
  • Class K: Calibration master, ±0.05 µm.

With class 1 gauge blocks (typical workshop set), angle accuracy becomes:

Δα ≈ ΔH / L (in radians)

For L = 100 mm and ΔH = 0.3 µm: Δα = 0.0000030 rad = 0.000172° = 0.62 arc seconds.

For comparison: an analog protractor typically has 1° resolution (3600 arc seconds). The sine bar vice is 6000× more accurate.

Rotating the base — 3D angle setting

The 360° rotatable base allows combined tilt + rotation. A practical example: milling a complex edge on a component specified as ”20° tilt in the XZ plane + 30° rotation around the Z axis”. With the sine bar vice, the setup is:

  1. The base is rotated 30° from the machine’s X axis via the protractor scale on the base rotation.
  2. The upper plate is tilted 20° via the sine principle with a gauge block stack (34.20 mm).
  3. The workpiece is clamped in the vice in the now 3D-positioned orientation.

The base rotation accuracy is typically ±0.05° (it is protractor-guided), while the sine tilt accuracy is sub-arcsecond. The combination is well above the requirements of most workshop tolerances.

Where the sine bar vice makes a real difference

Tool grinding: Cutting tools (lathe tools, mills, drills) have standard geometry with angle specifications of ±0.25-0.50°. The sine bar vice provides repeatable grinding with sub-degree accuracy.

Precision grinding: Grinding operations where edge angle is critical for function (e.g. tangent grinding on precision components).

Angle milling: CNC milling of edge chamfers, angled keyways, and complex-geometry components.

Angle inspection: QC of manufactured components — the component is clamped and verified against a reference angle block.

Calibration labs: Angle standards for further calibration of other angle measuring instruments.

Toolmaker workshops: Prototype and mold manufacturing where angle tolerance is critical.

Automotive component manufacturing: Engine components, transmission parts with angle-specific surfaces.

Aerospace industry: Aerodynamically angle-critical components (turbine blades, control surfaces).

Optical component grinding: Prism manufacturing where angle tolerances are very tight.

Medical instrument manufacturing: Surgical instruments and dental tools with angle-critical edges.

Practical handling and care

The sine bar vice is a precision component that requires disciplined handling:

  • Clean sine rollers: Dust or an oil film on the roller contact surfaces can cause µm errors that become 10× larger arc seconds in the angle.
  • Gauge block wringing: Gauge blocks in the stack should be ”wrung together” (adhering through molecular attraction without oil). Free play between blocks = wrong height.
  • Base plane inspection: The sine bar vice rests on a reference plane (granite plate or reference steel). If the base is scratched or not flat, the entire measurement becomes incorrect.
  • Jaw inspection: Keep vice jaws clean. Dust between jaws and workpiece = displacement.
  • Thermal stability: Both the sine bar vice and gauge blocks should be at temperature equilibrium (20 °C). A 5 °C temperature rise causes 5-6 µm expansion over a 100 mm sine base → 12 arc seconds of angle error.
  • Calibration verification: Annual verification of sine roller geometry and base plane against a reference lab. Scratched rollers must be replaced.

What you get for your money

Schut ECONOMY LINE universal sine bar vice 909.748, angle range 0-45°, 360° rotatable base, jaw opening 60 mm, jaw width 50 mm, jaw depth 25 mm, total length 140 mm, hardened steel (HRC 60+), ground reference surfaces and sine rollers with 100 mm nominal base length, compatible with DIN 861 gauge block sets in classes 0-2, compatible with ISO 17025 calibration certificates.

3,019 kronor is the investment in the instrument. Compared to a digital angle-setting instrument (5,000-15,000 kr, accuracy ±0.05°), the sine bar vice is half the price and 100-1000× more accurate — but requires a gauge block set (2,500-8,000 kr) for use. For a workshop that already has a gauge block set, the sine bar vice is a direct upgrade to sub-arcsecond precision.

Read more: Schut sine bar vice 909.748 in the shop →