Published July 11, 2026 at 12:38 PM
A 45 kW centrifugal pump has been in operation for 4 years at a district heating plant. The maintenance department receives a subjective report from the operators: ”the pump sounds a bit stranger than before.” What should the maintenance technician do? Without objective measurements, every action or inaction is guesswork. With a vibration meter compliant with the ISO 10816 standard, they get a number — RMS velocity in mm/s — that can be mapped directly to four classes: A (good), B (acceptable), C (unsatisfactory), D (unacceptable).
If the measurement shows 2.1 mm/s: class B — continue operation, re-measure in 3 months. If 3.8 mm/s: class C — plan replacement within 3-6 months. If 6.2 mm/s: class D — immediate action required, risk of catastrophic failure. This is the standardized decision process that ISO 10816 provides, and that the Extech SDL800-NIST vibration meter makes available in a handheld format.
Vibration physics: what you’re actually measuring
All rotating machinery vibrates. Under normal conditions, the vibration is small and regular. As mechanical problems develop — imbalance, misalignment, bearing wear, coupling play — the vibration increases in both amplitude and frequency content.
Vibration measurement can be expressed in three different units:
- Displacement (μm or mils): The amplitude of the vibration’s motion. Best for low frequencies (below 10 Hz) — motors, slow compressors.
- Velocity (mm/s RMS): The motion’s average speed. Best for mid frequencies (10-1000 Hz) — most pumps, motors, compressors.
- Acceleration (g or m/s²): The motion’s acceleration. Best for high frequencies (above 1000 Hz) — bearing fault spectra, gear mesh.
ISO 10816 uses RMS velocity in mm/s because it is the best universal indicator for medium-sized machines. The SDL800 measures this primary parameter.
What RMS velocity actually is
Vibration is an oscillating motion: the sensor detects the position changing over time. RMS (Root Mean Square) is a mathematical average:
v_RMS = √(⟨v(t)²⟩)
Where v(t) is the instantaneous velocity and ⟨…⟩ is the time average. RMS gives the ”energy-equivalent” constant velocity — the same as what the DC equivalent of an AC signal would be.
For a pure sinusoidal vibration with amplitude A: v_RMS = A/√2 ≈ 0.707A. For more complex vibration signatures (typical of faulty equipment) the ratio differs, and that in itself is diagnostic.
ISO 10816: the class table
ISO 10816 (specifically 10816-3 for medium-sized machines) defines four classes based on RMS velocity:
Class 1: Small machines (< 15 kW)
- A (good): < 0.71 mm/s
- B (acceptable): 0.71-1.8 mm/s
- C (unsatisfactory): 1.8-4.5 mm/s
- D (unacceptable): > 4.5 mm/s
Class 2: Medium-sized machines (15-75 kW)
- A: < 1.12 mm/s
- B: 1.12-2.8 mm/s
- C: 2.8-7.1 mm/s
- D: > 7.1 mm/s
Class 3: Large machines (75-300 kW) on rigid foundations
- A: < 1.4 mm/s
- B: 1.4-3.5 mm/s
- C: 3.5-7.1 mm/s
- D: > 7.1 mm/s
Class 4: Large machines on flexible foundations
- A: < 2.3 mm/s
- B: 2.3-4.5 mm/s
- C: 4.5-11.2 mm/s
- D: > 11.2 mm/s
Class A: design-level parameter for new machines. Class B: acceptable for continuous operation. Class C: reduced operating time; plan replacement. Class D: urgent action; risk of failure.
The SDL800’s frequency range: 10 Hz-1 kHz
The SDL800 measures vibration in the 10 Hz – 1 kHz frequency band. What falls inside and outside this band?
Inside (10 Hz – 1 kHz):
- Motor imbalance (typically rotor frequency): 25-50 Hz for 4-pole 50 Hz motors.
- Coupling faults (2× rotor frequency): 50-100 Hz.
- Looseness, mechanical resonance: broadband 10-500 Hz.
- Bearing faults at low-frequency bearings (BPFO, BPFI for ball bearings, typically 50-500 Hz).
- Bent shaft conditions: 25-200 Hz.
Outside (above 1 kHz):
- High-frequency bearing faults (cavitation, sliding friction) – 2-15 kHz.
- Gear mesh (gear tooth) – can be 500-5000 Hz depending on speed.
The SDL800 captures most pump and motor problems within its 10 Hz-1 kHz band. For early detection of microscopic bearing faults, specialized instruments with a 15 kHz range are needed (typically 50,000+ SEK).
Remote sensor with magnetic adapter — the workflow
The SDL800 comes with an RC piezoelectric vibration sensor on a 1.2 m cable. The sensor has a BUILT-IN PERMANENT MAGNET in its base. Here’s how it’s used in practice:
- The instrument is switched on and the mode (RMS/Peak/Max Hold) is selected.
- The sensor is placed magnetically against the MOTOR’S BEARING HOUSING (drive end or shaft end).
- The instrument shows the RMS velocity directly on the LCD display.
- Note the value.
- Move the sensor to the motor’s other bearing housing.
- Repeat for the pump bearings if it’s a pump.
- Compare all values against the ISO 10816 class table for the motor size class.
Total time per motor: 2-4 minutes for a full measurement.
The magnetic mount is critical because the measurement requires a RIGID CONTACT between the sensor and the bearing housing. If the sensor is held by hand, the vibration is dampened and the signal becomes unreliable. The magnetic probe provides 5-8 kg of contact force against the surface — sufficient for a rigid mechanical coupling.
Three measurement modes
RMS mode: Standard for ISO 10816 classification. Gives the value that maps directly to the class table.
Peak mode: Shows the highest instantaneous amplitude during the measurement period. Critical for detecting intermittent problems (damage cycles from faulty bearings, transient imbalances).
Max Hold mode: Locks in the highest measured value over the entire measurement period and keeps it on the display. Useful when measuring in hard-to-reach places where you can’t read the display while holding the sensor at the same time.
Frequency band filtering: what the SDL800 CANNOT do
The SDL800 gives you a single RMS figure across the entire 10-1000 Hz band. What it does NOT do is FFT analysis (Fast Fourier Transform) — meaning it does not show WHICH frequencies dominate. For full diagnostics, an FFT vibration analyzer (typically 30,000-100,000 SEK) is needed, which can show:
- Rotor frequency (1× rpm) — imbalance indicator.
- 2× rpm — coupling faults or mechanical looseness.
- Bearing fault frequencies (BPFO, BPFI, BSF, FTF) — specific bearing fault frequencies.
- Gear mesh frequencies — tooth wear or tooth breakage.
- High-frequency bands — cavitation, air entrainment in pumps.
The SDL800 gives you OK/not-OK; an FFT analyzer gives you the EXACT CAUSE. For a facility with 5-15 critical machines, the SDL800 is sufficient for first-level triage; for facilities with hundreds of critical machines, an FFT analyzer is a worthwhile investment.
NIST calibration certificate
The NIST variant of the SDL800 comes with a traceable calibration certificate from the US National Institute of Standards. This is mandatory for:
- ISO 9001-certified facilities where all measuring instruments must be traceably calibrated.
- Accreditation programs in the food, pharmaceutical, and nuclear power industries.
- Insurance-driven maintenance optimization where measurements form the basis for risk assessment.
- Legally verifiable documentation in disputes over equipment condition.
Recommended recalibration interval: annual. Cost approximately 800-1,500 SEK at an accredited lab.
20 million measurement values on SD card
The SDL800 stores data on an SD card in Excel-compatible format. Capacity: 20 million measurement values. Practical implications:
- At 1-second sampling over 24-hour monitoring: 86,400 points, well under capacity.
- At 1-minute sampling over a month: 43,200 points.
- At 15-minute sampling over a year: 35,000 points.
SD card storage is effectively unlimited in practical scenarios. Data import to Excel or other analysis tools is straightforward (just insert the card into a computer).
Applications
District heating plants: Pumps, circulation motors, fans for heat exchangers.
Water treatment and wastewater plants: Large pumps, compressors, blower fans.
Industrial process maintenance: Paper mills, mining, cement industry, steel plants.
HVAC installation maintenance: Large ventilation fans, compressor-based cooling systems.
Property maintenance (large buildings): Ventilation, elevators, circulation motors.
Marine and offshore maintenance: Propulsion motors, auxiliary machinery, generator sets.
Food industry: Mixers, conveyor belts, pumps, homogenizers.
Machine shops: CNC spindle vibration monitoring after collisions or suspected wear.
Power plants: Turbines, generators, feed pumps.
What you get for your money
Extech SDL800-NIST vibration meter with traceable NIST calibration certificate, RC piezoelectric remote sensor with permanent-magnet mount on a 1.2 m cable, frequency range 10 Hz-1 kHz, measurement modes RMS velocity (mm/s), Peak value and Max Hold, complies with ISO 2954 for vibration measurement, ±5% + 2 digit accuracy, SD card storage for 20 million values in Excel format, backlit LCD, MIN/MAX/Data Hold functions, automatic shut-off, USB connection to PC, double-molded housing, 6 AA batteries, hard carrying case included. 20,311 SEK.
The standard instrument for PDM (predictive maintenance) in industrial and commercial maintenance. With ISO 10816-based direct classification, no expert-level interpretation is required for first-level triage — the value maps directly to the A/B/C/D class. Complements a tachometer + IR thermometer (like the Extech RPM10) for a more complete PDM workflow, with vibration measurement as the third critical parameter in motor diagnostics.