Published 14 July 2026 at 22:40
Illuminance (light intensity, symbol E) is measured in Lux (SI unit, defined as lumen per square meter). It is one of the most fundamental measurements in workplace and building engineering — workplace lighting determines productivity, safety, and eye health of staff.
Although lux measurement may seem simple at first glance, it has two subtle complications that make an advanced meter worthwhile:
- Flicker from 50/60 Hz mains: Fluorescent lamps and older LED fixtures are modulated at the mains frequency. A quick lux reading only captures a single snapshot of the flickering signal.
- Spectral sensitivity: Sensors must match the human sensitivity spectrum (the V(λ) curve) for the LUX value to correspond to perceived brightness.
Workplace lighting requirements
The Swedish Work Environment Authority (AFS 2020:1 Workplace Design) requires specific minimum illuminance levels per work area. Based on the Swedish Lighting Association’s recommendations (SS-EN 12464-1:2021):
- Passages, walkways, corridors: 100 lux minimum.
- General office lighting: 300 lux.
- Desks, screen work: 500 lux.
- Conference rooms: 500 lux.
- Detailed workshop work: 750-1000 lux.
- Fine assembly work, microelectronics: 1000-2000 lux.
- Precision measurement in labs: 1500 lux.
- Operating theatre: 10,000-100,000 lux (dedicated surgical lamp).
Reference outdoor values:
- Full sun: 100,000 lux.
- Overcast day: 10,000-30,000 lux.
- Dusk: 100-500 lux.
- Full moon night: 0.25-1 lux.
Ripple function — 50/100 Hz flicker elimination
This is the EA33’s most distinctive feature and biggest technical differentiator versus cheap lux meters.
Fluorescent lamps are driven by 50 Hz mains voltage that modulates light intensity twice per cycle — i.e. 100 Hz flicker. Standard LED fixtures typically run at 100-300 Hz PWM frequency depending on the driver electronics.
A quick (10-50 ms) lux reading only captures a single snapshot of this flickering signal. At some phases the reading is 400 lux, at others 600 lux — same fixture, same surface, different values.
The Ripple function activates an INTEGRATING measurement window (typically 1-2 seconds = 100-200 flicker cycles) that averages the lux value without artifacts from flicker.
Without Ripple: standard readings vary ±10-20%. With Ripple: stable reading within ±1%.
Critical for workplace lighting verification where the measurement must be DOCUMENTED. Without Ripple integration, the operator may get different values on two measurements of the same fixture, casting doubt on the validity of the documentation.
Range 0 – 999,900 lux
Six decades of range cover practically every scenario:
- 0.01-999 lux: office lighting, darkroom lab.
- 1,000-9,999 lux: detailed workshop lighting.
- 10,000-99,999 lux: outdoor lighting, industrial hall.
- 100,000-999,999 lux: direct sunlight, operating theatre lamps.
Resolution:
- 0-9.99 lux: 0.01 lux resolution.
- 10-99.9 lux: 0.1 lux.
- 100-999 lux: 1 lux.
- 1000-9999 lux: 10 lux.
- And so on.
Automatic range switching — the operator does not need to manually select the measurement range.
Candela calculation for point light sources
Candela (cd) is the unit for LUMINOUS INTENSITY from a point source — a more fundamental way to characterize lamps than total emitted lumens.
The formula: luminous intensity (cd) = illuminance (lux) × distance² (m²).
Practical use:
- Place the sensor at distance d from the lamp.
- Read the lux value E.
- Calculate cd = E × d².
The EA33 performs this calculation automatically once the operator enters the distance.
Standard references:
- Candle: ~1 cd.
- Household 60W incandescent bulb: ~60 cd.
- Car headlight: 1000-2000 cd.
- Lighthouse: 10⁶-10⁸ cd.
Data logging with real-time clock
50 measurements can be stored internally with a timestamp (real-time clock). This enables systematic mapping of a workplace:
- Measure lighting at work area 1 (10:23 – office desk, center).
- Measure lighting at work area 2 (10:25 – office desk, edge).
- …
- Measure lighting at work area 47.
- All values stored with timestamp.
- Report generated with data transfer to computer.
Option: measurement CAN be made absolute or RELATIVE to a reference surface:
- Absolute measurement: current lux value.
- Relative (%): deviation from a pre-set reference (typically: ”how much worse is this position compared to the center of the work area?”).
Comparator function with high/low alarm
The operator can set TWO threshold values:
- Low alarm: the instrument beeps if the value is BELOW the threshold (e.g. 300 lux minimum for office lighting).
- High alarm: the instrument beeps if the value is ABOVE the threshold (e.g. 2000 lux max to avoid glare).
Practical use: walk around a building and the alarms directly indicate which positions are out of spec — faster than writing down every value and analyzing afterward.
The V(λ) curve and sensor calibration
The human eye has varying sensitivity to different wavelengths. Maximum sensitivity is at ~555 nm (green-yellow), falling off toward both red (700 nm, ~30% sensitivity) and blue (400 nm, ~5%).
This spectral curve is called V(λ) and is standardized by the CIE (Commission Internationale de l’Éclairage). The LUX unit is DEFINED using this curve as its weighting function.
Quality lux meters (such as the EA33) have a sensor with a spectral filter matched to the V(λ) curve. This means the LUX reading actually corresponds to PERCEIVED brightness, not just total optical power.
Cheap lux meters use a standard photodiode without spectral filtering. Their reading differs for different light types:
- For incandescent bulbs (broad spectrum): reasonably close to correct.
- For fluorescent (line spectrum): 10-20% error.
- For RGB LED fixtures: can be 30-50% error if the spectrum is atypical.
The EA33 has a V(λ)-matched sensor for accurate readings regardless of the light source’s spectrum.
Applications
Workplace lighting verification: The standard tool for health & safety inspectors, building surveyors, and occupational health services. Verification of lighting levels according to AFS 2020:1 and SS-EN 12464-1.
Building renovation — lighting planning: New lighting systems are verified after installation to confirm that designed lux levels are achieved.
Photography studios: Verification of portrait and product photography lighting.
Photo booth and studio calibration: Standardized lighting for consistent image quality.
Greenhouse and cultivation industry: LED grow lights for hydroponic cultivation. Optimal lux value per crop.
Film production — set lighting: Verification of even lighting across the scene area for consistent image exposure.
Educational facilities: Classrooms, laboratories, workshop teaching must have appropriate lighting for learning.
Hospitals and operating theatres: Verification of surgical lamp brightness and evenness.
Museums and art galleries: Balance between sufficient lighting for visitors and preservation of artwork (too much light fades pigments).
Entertainment and performing arts: Verification of stage lighting for audience viewing comfort.
Airports and train stations: Lighting for safe orientation and sign reading.
Scientific research: Controlled lighting for biological experiments (e.g. circadian rhythm research on laboratory animals).
Choosing between Lux and Foot-Candle (Fc)
The EA33 supports BOTH units:
- Lux (SI, European standard): 1 lm/m².
- Foot-Candle (imperial, American standard): 1 lm/ft². 1 Fc = 10.764 lux.
The choice between units is cultural — the Swedish and European market uses lux, the American market uses Fc. The EA33’s dual-unit capability makes it useful internationally.
Specifications
- Measurement range: 0-999,900 lux (0-99,990 Fc).
- Resolution: 0.01 lux (lowest range) / 0.001 Fc.
- Accuracy: typically ±5% + 2 digits (for V(λ)-matched sensor).
- Sensor: silicon photodiode with V(λ) compensation filter.
- Ripple function: actively filters 50/100 Hz flicker.
- Candela calculation: automatic from lux + distance.
- Memory: 50 measurements with real-time clock.
- Comparator: programmable high/low alarm.
- Relative measurement: % deviation or absolute difference from reference.
- Large backlit LCD.
- Data output to Windows PC.
What you get for the money
Extech EA33 Lux/light meter, measurement range 0-999,900 lux (0-99,990 Fc), 0.01 lux resolution, V(λ)-matched sensor for accurate readings regardless of light source spectrum, Ripple function for 50/100 Hz flicker elimination, automatic Candela calculation, 50-measurement memory with real-time clock, high/low alarm comparator, dual-unit support (Lux + Foot-Candle), large backlit LCD, data output to PC. 5,036 SEK.
The standard tool for health & safety inspectors, lighting designers, building surveyors, work environment specialists, photographers, and other applications requiring DOCUMENTED illuminance measurement according to AFS 2020:1, SS-EN 12464-1, or equivalent international standards. The price premium over a cheap lux meter (200-800 SEK) is justified by the Ripple function, V(λ) sensor compensation, and memory for systematic workplace mapping.
Read more: Extech EA33 Lux meter in the shop →