Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsStale air in the meeting room is a measurable number, and the dew point decides whether a surface stays glossy or turns mistyVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsStale air in the meeting room is a measurable number, and the dew point decides whether a surface stays glossy or turns misty
Item number 56-TR-52I

TandD Compact waterproof temperature logger with external probe. -60 to +155 °C depending on probe

1.740 SEK

In stock

TandD Compact waterproof temperature logger with external sensor. -60 to +155 °C depending on sensor

Request a quote 56-TR-52I

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category: , , ,

Other models in the series 4

Description

The 56-TR-52I is TandD’s compact single-channel logger for temperature with an external probe on cable — featuring the same robust design as the 56-TR-51I but with the probe separated from the electronics, allowing you to measure in locations where the logger unit does not fit or would be damaged. The measuring range extends from -60 to +155 °C, depending on the probe used.

A standard probe is included. Powered by an LS14250 lithium cell for approximately 4 years. Data retrieval requires the communication holder 56-TR-50U2 (sold separately) — optical data transfer eliminates the risk of short circuits caused by wet contacts.

Features

  • External thermistor probe on cable (included)
  • Measuring range -60 to +155 °C (probe-dependent)
  • Fast response time: approx. 80 seconds in air, approx. 7 seconds in stirred water
  • Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C / ±1.0 °C in extreme ranges
  • IP64 splash protection on the logger unit
  • 4-year battery life on a single LS14250
  • 16,000 data points
  • 15 fixed logging intervals (1 second to 60 minutes)
  • Built-in LCD and alarm LED
  • Optical communication via 56-TR-50U2

Specification

Measuring channel Temperature 1 channel — thermistor (external, on cable)
Measuring range -60 to +155 °C (probe-dependent)
Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C / ±1.0 °C (extreme ranges)
Resolution 0.1 °C
Response time (90 %) approx. 80 sec in air / approx. 7 sec in stirred water
Logging capacity 16,000 data points
Communication Optical (requires 56-TR-50U2)
Protection class IP64 (logger unit)
Power supply Lithium battery LS14250 × 1 (included)
Battery life approx. 4 years
Dimensions 62 × 47 × 19 mm (excl. probe)

Included

  • 56-TR-52I logger with external temperature probe
  • 1 × Lithium battery LS14250
  • Manual set with warranty certificate
  • NOTE: 56-TR-50U2 holder required for PC connection

Applications

The 56-TR-52I is suitable for applications where you need to measure outside the -40/+80 °C range or need to place the probe at a specific point. Typical applications: ovens, freezers with the probe placed inside the product itself, heating circuits, autoclaves. For the modern Bluetooth version, see 56-TR42A. For a built-in probe instead, see 56-TR-51I.

Additional information
Product Type

Measures

Temperature

Communication

Optical

PDF (1)