Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in seconds
Item number 52-PA203X-006-009-016-019

Palm Abbe Digital Refractometer for Antifreeze: Glycerin & Propylene Glycol in Volume Percent & Freezing Point °C

6.965 SEK

In stock

Celsius model – The Palm Abbe Glycerin & Propylene Glycol Refractometer is designed to provide the freezing point and percentage concentration of both glycerin and propylene glycol antifreeze solutions. This instrument tests the volume percentage concentration and freezing point in degrees Celsius for glycerin and propylene glycol.

Request a quote 52-PA203X-006-009-016-019

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Description
Scale Medium Unit of Measure Display Shows Measuring Range Resolution Accuracy
006 Propylene Glycol % Volume/Volume PG % v/v 0 to 100 0.1 0.1
009 Propylene Glycol Freezing Point °C PG Freeze °C 0 to -51 1 1
016 Glycerin % Volume/Volume Glycerine %v 0 to 100 0.1 0.1
019 Glycerin Freezing Point °C Glycerin °C 0 to -43 1 1

Digital Refractometer Measures Glycerine & Propylene Glycol % Volume and Freeze Point in Celsius

Keep your coolant measurements under control!

The Palm Abbe is a fourth-generation digital handheld refractometer that places laboratory precision in the palm of your hand. Not just laboratory precision, but laboratory precision at the price of a traditional analog refractometer. It is exactly the kind of robust, groundbreaking technology you expect from MISCO, the company that paved the way for digital handheld refractometers.

Simply place one or two drops of glycerin (glycerol) or propylene glycol in the stainless steel sample well and press a button. The specially designed microprocessor provides an almost immediate reading of the glycerin or propylene glycol concentration or freezing point. Non-linear temperature compensation is automatic and ensures that liquids tested between 0 and 50 °C (32 to 122 °F) are measured accurately.

Glycerin and propylene glycol concentration and freezing point are easy to read on the large dual-line LCD display, even in low light. Digital readings eliminate the subjectivity associated with interpreting where a boundary line crosses small scale divisions. And it is so easy to use! The user interface consists of two buttons, one for readings and the other to step through various menu options.

Calibration is automatic and does not require the use of special calibration solutions or tools. The Palm Abbe refractometer calibrates automatically to water and is ready to use within seconds. No more screw adjustments and nothing to tweak.

Specification
Scale Medium Unit of Measure Display Shows Measuring Range Resolution Accuracy
006 Propylene Glycol % Volume/Volume PG % v/v 0 to 100 0.1 0.1
009 Propylene Glycol Freezing Point °C PG Freeze °C 0 to -51 1 1
016 Glycerin % Volume/Volume Glycerine %v 0 to 100 0.1 0.1
019 Glycerin Freezing Point °C Glycerin °C 0 to -43 1 1

Digital Refractometer Measures Glycerine & Propylene Glycol % Volume and Freeze Point in Celsius

Keep your coolant measurements under control!

The Palm Abbe is a fourth-generation digital handheld refractometer that places laboratory precision in the palm of your hand. Not just laboratory precision, but laboratory precision at the price of a traditional analog refractometer. It is exactly the kind of robust, groundbreaking technology you expect from MISCO, the company that paved the way for digital handheld refractometers.

Simply place one or two drops of glycerin (glycerol) or propylene glycol in the stainless steel sample well and press a button. The specially designed microprocessor provides an almost immediate reading of the glycerin or propylene glycol concentration or freezing point. Non-linear temperature compensation is automatic and ensures that liquids tested between 0 and 50 °C (32 to 122 °F) are measured accurately.

Glycerin and propylene glycol concentration and freezing point are easy to read on the large dual-line LCD display, even in low light. Digital readings eliminate the subjectivity associated with interpreting where a boundary line crosses small scale divisions. And it is so easy to use! The user interface consists of two buttons, one for readings and the other to step through various menu options.

Calibration is automatic and does not require the use of special calibration solutions or tools. The Palm Abbe refractometer calibrates automatically to water and is ready to use within seconds. No more screw adjustments and nothing to tweak.