Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readings
Item number 52-CALFLU202-3

Calibration Fluid for MISCO Digital Handheld Refractometers

1.048 SEK

In stock
Request a quote 52-CALFLU202-3

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category: ,

Description

The CALFLU202-3 is a specialized calibration fluid designed for calibrating the span (high-end) point of MISCO Palm Abbe digital refractometers. Although it is important to perform a Zero-Set on Palm Abbe refractometers using water daily, you may occasionally need to adjust the span setting.

The refractometer’s span should be adjusted if you notice a general degradation in the instrument’s accuracy and precision, or on a regular basis determined by your specific usage history with the instrument. It is recommended to perform this adjustment once per year to maintain maximum measurement precision.

Factors influencing your decision to adjust the span include how frequently the instrument is used, how roughly it is handled, how often it is exposed to significant temperature changes, and the level of accuracy required for your measurements. When performing a span adjustment, it is crucial to keep both the instrument and the calibration fluid as close to 20 °C (68 °F) as possible; the temperature should never deviate by more than a few degrees from this value.

Specification

The CALFLU202-3 is a specialized calibration fluid designed for calibrating the span (high-end) point of MISCO Palm Abbe digital refractometers. Although it is important to perform a Zero-Set on Palm Abbe refractometers using water daily, you may occasionally need to adjust the span setting.

The refractometer’s span should be adjusted if you notice a general degradation in the instrument’s accuracy and precision, or on a regular basis determined by your specific usage history with the instrument. It is recommended to perform this adjustment once per year to maintain maximum measurement precision.

Factors influencing your decision to adjust the span include how frequently the instrument is used, how roughly it is handled, how often it is exposed to significant temperature changes, and the level of accuracy required for your measurements. When performing a span adjustment, it is crucial to keep both the instrument and the calibration fluid as close to 20 °C (68 °F) as possible; the temperature should never deviate by more than a few degrees from this value.