AR700 Palm Abbe Digital Refractometer Bench Model: Measures Brix and Refractive Index
Call for price
The AR700 is equipped with built-in Peltier electronic temperature control to eliminate the need for a water bath circulator and to improve accuracy. With an accuracy of 0.00005 refractive index and 0.03 Brix. The extended measurement range of 1.33000 to 1.60000 for refractive index and 0 to 95 Brix covers most applications.
- Free shipping on orders over 3000 SEK excl. VAT
- Measuring instruments and gauges for professionals
- Call us +46 8 753 00 04
Description
52-AR700
52-AR700
AR700 Automatic Refractometer
The Reichert AR700 Automatic Refractometers are among the most technically advanced instruments for measuring refractive index, Brix, or equivalent concentration units. These instruments feature an advanced Peltier temperature control system that allows the user to manually set the desired operating temperature on an easy-to-use graphical display. Within moments, the instrument stabilizes at the set temperature, eliminating the need for an external water bath circulator. The temperature can be set from 10 to 100 degrees Celsius.
Automatic temperature equilibration detection allows the user to load a warm or cold sample and immediately press the Read button. The sample temperature is monitored until an equilibrium state has been reached with the instrument, at which point the measurement is taken. This ensures the highest level of measurement accuracy without the need for a technician to monitor the temperature or set a timer.
Advanced optics (including a sapphire prism for a virtually indestructible sample interface and a 3600 cell) provide incredible accuracy of ± 0.00001 refractive index and ± 0.01 Brix. This is achieved across the full measurement range of 1.33000 to 1.60000 for refractive index and the full Brix range.
While these features are ideal for research and development departments, these instruments are also well-suited for production lines. With an incredibly easy-to-use, user-friendly software system and graphical LCD screen, anyone can operate the AR700 Automatic Refractometer accurately and safely. Extensively tested across the food and beverage, chemical, and pharmaceutical markets.
Key Features
Built-in Peltier temperature control (user-defined, 10 to 100 degrees Celsius) – Reduces operating costs by eliminating the need for an external water bath circulator. Improves accuracy and simplicity of temperature regulation. Reduces the amount of bench space required for operation.
Fully automatic readings, including Automatic temperature equilibration detection – Reduced operator error. No more shadowlines to interpret and no more countdown timers to monitor. Simply load the sample and press READ; the instrument monitors the sample to ensure stability, then takes a fully automatic reading. Can read all samples, including transparent, translucent, and opaque liquids.
Sapphire prism and stainless steel sample well – Reduced maintenance costs. The sample measuring surface and sample well are virtually indestructible.
1.33000 to 1.60000 for refractive index (Full Brix range per ICUMSA) – The extended reading range ensures that virtually all samples can be analyzed on a single instrument.
Custom scale capability (storage of up to 14 unique scales) – Users can program these units with correlation formulas to convert refractive index and temperature into concentration. Hundreds of scales are available, or users can create their own for their unique products. Readability and measurement unit names are user-defined.
Five buttons with graphical display and simple, user-friendly software – Extreme ease of use for anyone from swing shift production line operators to laboratory technicians and researchers, while offering flexibility in supervisor-controlled sample analysis protocols.
Universal AC adapter transformer – Operates from all power sources from 100 to 220 volts and 50/60 Hz.
Two models are now available; choose the one that best fits your application:
-AR700 with precision of 0.01 Brix or 0.00001 Refractive Index
-AR70 with precision of 0.1 Brix or 0.0001 Refractive Index.
Specification
52-AR700
52-AR700
AR700 Automatic Refractometer
The Reichert AR700 Automatic Refractometers are among the most technically advanced instruments for measuring refractive index, Brix, or equivalent concentration units. These instruments feature an advanced Peltier temperature control system that allows the user to manually set the desired operating temperature on an easy-to-use graphical display. Within moments, the instrument stabilizes at the set temperature, eliminating the need for an external water bath circulator. The temperature can be set from 10 to 100 degrees Celsius.
Automatic temperature equilibration detection allows the user to load a warm or cold sample and immediately press the Read button. The sample temperature is monitored until an equilibrium state has been reached with the instrument, at which point the measurement is taken. This ensures the highest level of measurement accuracy without the need for a technician to monitor the temperature or set a timer.
Advanced optics (including a sapphire prism for a virtually indestructible sample interface and a 3600 cell) provide incredible accuracy of ± 0.00001 refractive index and ± 0.01 Brix. This is achieved across the full measurement range of 1.33000 to 1.60000 for refractive index and the full Brix range.
While these features are ideal for research and development departments, these instruments are also well-suited for production lines. With an incredibly easy-to-use, user-friendly software system and graphical LCD screen, anyone can operate the AR700 Automatic Refractometer accurately and safely. Extensively tested across the food and beverage, chemical, and pharmaceutical markets.
Key Features
Built-in Peltier temperature control (user-defined, 10 to 100 degrees Celsius) – Reduces operating costs by eliminating the need for an external water bath circulator. Improves accuracy and simplicity of temperature regulation. Reduces the amount of bench space required for operation.
Fully automatic readings, including Automatic temperature equilibration detection – Reduced operator error. No more shadowlines to interpret and no more countdown timers to monitor. Simply load the sample and press READ; the instrument monitors the sample to ensure stability, then takes a fully automatic reading. Can read all samples, including transparent, translucent, and opaque liquids.
Sapphire prism and stainless steel sample well – Reduced maintenance costs. The sample measuring surface and sample well are virtually indestructible.
1.33000 to 1.60000 for refractive index (Full Brix range per ICUMSA) – The extended reading range ensures that virtually all samples can be analyzed on a single instrument.
Custom scale capability (storage of up to 14 unique scales) – Users can program these units with correlation formulas to convert refractive index and temperature into concentration. Hundreds of scales are available, or users can create their own for their unique products. Readability and measurement unit names are user-defined.
Five buttons with graphical display and simple, user-friendly software – Extreme ease of use for anyone from swing shift production line operators to laboratory technicians and researchers, while offering flexibility in supervisor-controlled sample analysis protocols.
Universal AC adapter transformer – Operates from all power sources from 100 to 220 volts and 50/60 Hz.
Two models are now available; choose the one that best fits your application:
-AR700 with precision of 0.01 Brix or 0.00001 Refractive Index
-AR70 with precision of 0.1 Brix or 0.0001 Refractive Index.


There are no reviews yet.