Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in seconds
Item number 56-RTR505B

TandD Wireless Multifunction Logger — Used with interchangeable input modules (Pt, thermocouple, voltage, current, pulse). Range up to 150 m, Bluetooth

1.648 SEK

In stock

TandD Wireless Multifunction Logger — used with interchangeable input modules (Pt, thermocouple, voltage, current, pulse). Range up to 150 m, Bluetooth

Request a quote 56-RTR505B

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category: , , ,

Other models in the series 2

Description

The 56-RTR505B is TandD’s most flexible wireless logger — a platform that you customize to your measurement needs by selecting an input module. Do you need to measure high temperatures with a thermocouple? Industrial Pt100? 0–20 V analog voltage? 4–20 mA current loop? Pulse counting from a flow meter? Same logger, just swap the module. When the project changes or a sensor fails, you can buy a new module instead of a whole logger.

Note: The input module is sold separately — choose according to your application. Measurement data is transmitted wirelessly via radio (EU: 869.7–870 MHz) to any RTR-500B base unit at a direct line-of-sight distance of up to 150 meters.

Available input modules

  • 56-PTM-3010 — Pt100 / Pt1000 (3- or 4-wire), -199 to +600 °C, high precision over a wide temperature range
  • 56-TCM-3010 — Thermocouple types K, J, T, S, -199 to +1760 °C
  • 56-VIM-3010 — DC voltage 0 to 22 V, resolution 0.1 mV, with preamplification and scaling function
  • 56-AIM-3010 — Current loop 4–20 mA (operational up to 40 mA), scaling
  • 56-PIC-3150 — Pulse counting cable (0 to 61,439 counts), contact or voltage input

Features

  • Modular platform — select measurement function via input module
  • 1 measurement channel via selected module
  • Wireless range approx. 150 meters line-of-sight
  • 16,000 data point memory (Endless mode)
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • Battery life approx. 10 months on LS14250
  • Built-in LCD displays current value and battery warning
  • Bluetooth 4.2 BLE for configuration via mobile app

Specification

Measurement function Temperature (Pt or thermocouple), Voltage, 4–20 mA, or Pulse counting — depending on selected input module
Measurement range Depending on module: -199 to +1760 °C (thermocouple), -199 to +600 °C (Pt), DC 0–22 V (voltage), 0–20 mA (current), 0–61 439 counts (pulse)
Logging capacity 16 000 data points
Logging mode Endless or One Time
Logging interval 15 options: 1, 2, 5, 10, 15, 20, 30 sec or 1, 2, 5, 10, 15, 20, 30, 60 min
Wireless communication EU: 869.7–870 MHz, RF power 5 mW, range approx. 150 m
Other interfaces Bluetooth 4.2 BLE, optical communication
Power supply Lithium battery LS14250 × 1 (included)
Battery life approx. 10 months
Dimensions 62 × 47 × 19 mm (excl. protruding parts and module)
Weight approx. 50 g
Operating environment -40 to +80 °C (during wireless transmission: -30 to +80 °C)
Compatible base units 56-RTR500BC, 56-RTR500BW, 56-RTR500BM

Included

  • 56-RTR505B logger
  • 1 × Lithium battery LS14250
  • Strap for hanging
  • Manual set with warranty certificate
  • NOTE: input module sold separately — order together

Applications

The 56-RTR505B is suitable for industrial process monitoring and laboratory environments where measurement requirements vary or where multiple probe types are used in parallel — e.g., the same logger for Pt100 in an oven, then reconfigured for a 4–20 mA flow meter when the project changes direction. Classic applications: heat treatment with thermocouples, industrial temperature measurements with Pt100, energy mapping with pulse counters on electricity meters, flow monitoring with 4–20 mA meters, voltage monitoring of battery backup. For longer battery life (4 years), see 56-RTR505BL.

Additional information
Product Type

Measures

Pulse Counting, Voltage V, Current 4-20 mA

Communication

Wireless Bluetooth, Wireless Long Range