Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frost
Item number 56-TR-72NW

TandD Logger for temperature and humidity, wired Ethernet/LAN. 0–55 °C, 10–95 %RH. Cloud connectivity

3.070 SEK

In stock

TandD Logger for temperature and humidity, wired Ethernet/LAN. 0–55 °C, 10–95 %RH. Cloud connectivity

Request a quote 56-TR-72NW

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category: , , , ,

Other models in the series 4

Description

The 56-TR-72NW is TandD’s Ethernet-connected logger for temperature and humidity — connect the network cable directly and let the logger automatically upload data to the T&D WebStorage cloud or an internal PC using T&D Data Server. PoE support (IEEE 802.3af) provides power via the network cable.

The included T/RH sensor 56-THA-3001 offers standard accuracy of ±0.5 °C / ±5 %RH in the range of 0–55 °C / 10–95 %RH — suitable for most indoor monitoring applications (offices, warehouses, data centers, grocery stores).

Features

  • External T/RH sensor 56-THA-3001 included
  • Temperature measuring range: 0 to +55 °C
  • Humidity measuring range: 10 to 95 %RH
  • Accuracy ±0.5 °C / ±5 %RH (at 25 °C, 50 %RH)
  • Wired Ethernet 10/100 Mbps (RJ45)
  • PoE IEEE 802.3af
  • Memory for 16,000 data points
  • 15 fixed logging intervals + 15 upload intervals
  • Battery life up to approx. 1 year with 12-hour uploads
  • USB 2.0 Mini-B for configuration
  • Built-in LCD with alternating display of temperature and RH

Specification

Measuring channels Temperature 1 channel (thermistor) + Humidity 1 channel (polymer) — external, on cable
Measuring range 0 to +55 °C / 10 to 95 %RH
Accuracy ±0.5 °C / ±5 %RH (at 25 °C, 50 %RH)
Resolution 0.1 °C / 1 %RH
Logging capacity 16,000 data points
Network 10 Base-T / 100 Base-TX (RJ45)
Protocols HTTP (proxy supported), DHCP, DNS
Other interfaces USB 2.0 Mini-B
Power supply 2 × AA alkaline / Ni-MH, USB bus, AC adapter, PoE IEEE 802.3af
Battery life approx. 7 months (1 h charging), approx. 1 year (12 h / OFF)
Dimensions 58 × 78 × 26 mm
Weight approx. 55 g
Operating environment -10 to +60 °C, max 90 % RH non-condensing

Included

  • 56-TR-72NW logger
  • External T/RH sensor 56-THA-3001
  • 2 × AA alkaline batteries
  • USB Mini-B cable 56-US-15C
  • Manual set with warranty certificate

Applications

The 56-TR-72NW is suitable for fixed T/RH monitoring in environments with Ethernet access: server rooms, data centers, laboratories, offices, food storage, museums/archives with PoE infrastructure. For WiFi instead of LAN, see 56-TR72A2. For high precision (±2.5 %RH), see 56-TR-72NW-S.

Additional information
Product Type

Measures

% Relative Humidity, Temperature

Communication

Wired Ethernet

PDF (1)