Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readings
Item number 52-PA202X-185-629

Palm Abbe Digital Refractometer for Urea: Urea-based diesel exhaust fluid (AdBlue or DEF) for SCR catalysts and refractive index

5.795 SEK

In stock

Misco’s DEF-202 digital refractometer is an ideal method for testing and monitoring the concentration of urea-based Diesel Exhaust Fluid (DEF or AdBlue) required by diesel engines equipped with Selective Catalytic Reduction (SCR technology). This dual-scale refractometer features a DEF concentration scale and a refractive index scale.

Request a quote 52-PA202X-185-629

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Description
Scale Medium Unit of Measurement Display Shows Measuring Range Resolution Accuracy
185 Urea (NH2)2C0 % Weight/Weight Urea % wt. 0 to 51 0.1 0.1
629 Refractive Index – Urea Refractive Index nD R.I. (urea) 1.3330 to 1.4056 0.0001 0.0001

Urea refractometer for testing Urea-Based Diesel Exhaust Fluid (DEF / AdBlue) Concentration in SCR (Selective Catalytic Reduction) equipped Diesel engines

DEF-202 will outsmart those who try to cheat


Diesel Exhaust Fluid (DEF) is already a reality for trucks, buses, and vehicles powered by diesel engines. New Tier IV guidelines take effect in 2014 for off-road equipment. These regulations will affect excavators, bulldozers, skid steers, and other commercial construction machinery. Additionally, agricultural tractors and farm machinery, heavy forklifts, and airport ground service equipment are affected. Even diesel-powered stationary equipment such as generators, pumps, and compressors will be required to meet emission standards.

To comply with EPA regulations, engine manufacturers use Selective Catalytic Reduction, which requires a very precise concentration of liquid urea (DEF) to function correctly. Selective Catalytic Reduction systems utilize liquid urea, a nitrogen-based compound, to treat diesel exhaust before it enters a special catalyst. The liquid is known as Diesel Exhaust Fluid (DEF) in the USA and AdBlue® in Europe. It consists of a very specific concentration of aqueous urea solution in demineralized water. Injected into the hot exhaust gases as a fine mist, the urea breaks down into ammonia and converts harmful nitrogen oxides (NOx) into harmless nitrogen gas and water vapor.

The best defense against diluted DEF.

The proper concentration of Diesel Exhaust Fluid (DEF) is crucial to mitigating harmful NOx emissions and prolonging the life of the SCR components. Even concentration variations of as little as +/-0.8% will prevent a DEF fluid from meeting the specifications mandated by International Standards Organization (ISO). DEF dilution or contamination can impact system performance and maintenance costs. The biggest contamination threat is water dilution but without the proper tools it is nearly impossible to know if a DEF supply has been diluted.

Get concrete results in just seconds.

The MISCO Palm Abbe DEF-202 refractometer is the ideal method for testing DEF fluid to ensure it is at the correct concentration and that it has not been diluted or tampered with. It only takes a few drops of DEF and a couple of seconds to perform a test and the results are precise to +/-0.1% urea concentration.

Once a few drops of the sample have been added to the stainless steel prism, it only takes a single button press to initiate the measurement. Within seconds, the urea concentration will be displayed on the large 24-character backlit LCD display. The refractometer can also be calibrated for water with a single button press.

The key to precision and accuracy in the refractometer is MISCO’s proprietary Optic Motor®. A combination of high-index sapphire optics and a 1,024-element detector array. Special hardware and software automatically compensate for temperature in readings over a wide temperature range.

The ultimate choice for DEF testing.

Misco’s digital refractometer is the ideal instrument for testing DEF to prevent the use of fluid that is outside expected values. MISCO refractometers meet or exceed the requirements of ASTM D7821 – 12, Standard Test Method for Field Determination of Urea Concentration in Diesel Exhaust Fluid (DEF).


The American Petroleum Institute (API), a non-profit industry organization and advocate for the oil and natural gas industry, is charged with certifying manufacturers of Diesel Exhaust Fluid (DEF) for selective catalytic reduction (SCR) equipped diesel engines in North America. The best way to guarantee good DEF fluid is to only purchase urea bearing API certification and frequently test the fluid with a MISCO refractometer to ensure it meets quality requirements.

A refractometer can tell if it gives less environmental impact; it’s definitely DEF.

Options include; additional scales to measure urea density, specific gravity, and freezing point. As well as, engine coolant concentration and freezing point, brake fluid moisture content or boiling point, and windshield washer fluid. There is also a rubber armored jacket (in three different colors) and a virtually indestructible storage case.

Specification
Scale Medium Unit of Measurement Display Shows Measuring Range Resolution Accuracy
185 Urea (NH2)2C0 % Weight/Weight Urea % wt. 0 to 51 0.1 0.1
629 Refractive Index – Urea Refractive Index nD R.I. (urea) 1.3330 to 1.4056 0.0001 0.0001

Urea refractometer for testing Urea-Based Diesel Exhaust Fluid (DEF / AdBlue) Concentration in SCR (Selective Catalytic Reduction) equipped Diesel engines

DEF-202 will outsmart those who try to cheat


Diesel Exhaust Fluid (DEF) is already a reality for trucks, buses, and vehicles powered by diesel engines. New Tier IV guidelines take effect in 2014 for off-road equipment. These regulations will affect excavators, bulldozers, skid steers, and other commercial construction machinery. Additionally, agricultural tractors and farm machinery, heavy forklifts, and airport ground service equipment are affected. Even diesel-powered stationary equipment such as generators, pumps, and compressors will be required to meet emission standards.

To comply with EPA regulations, engine manufacturers use Selective Catalytic Reduction, which requires a very precise concentration of liquid urea (DEF) to function correctly. Selective Catalytic Reduction systems utilize liquid urea, a nitrogen-based compound, to treat diesel exhaust before it enters a special catalyst. The liquid is known as Diesel Exhaust Fluid (DEF) in the USA and AdBlue® in Europe. It consists of a very specific concentration of aqueous urea solution in demineralized water. Injected into the hot exhaust gases as a fine mist, the urea breaks down into ammonia and converts harmful nitrogen oxides (NOx) into harmless nitrogen gas and water vapor.

The best defense against diluted DEF.

The proper concentration of Diesel Exhaust Fluid (DEF) is crucial to mitigating harmful NOx emissions and prolonging the life of the SCR components. Even concentration variations of as little as +/-0.8% will prevent a DEF fluid from meeting the specifications mandated by International Standards Organization (ISO). DEF dilution or contamination can impact system performance and maintenance costs. The biggest contamination threat is water dilution but without the proper tools it is nearly impossible to know if a DEF supply has been diluted.

Get concrete results in just seconds.

The MISCO Palm Abbe DEF-202 refractometer is the ideal method for testing DEF fluid to ensure it is at the correct concentration and that it has not been diluted or tampered with. It only takes a few drops of DEF and a couple of seconds to perform a test and the results are precise to +/-0.1% urea concentration.

Once a few drops of the sample have been added to the stainless steel prism, it only takes a single button press to initiate the measurement. Within seconds, the urea concentration will be displayed on the large 24-character backlit LCD display. The refractometer can also be calibrated for water with a single button press.

The key to precision and accuracy in the refractometer is MISCO’s proprietary Optic Motor®. A combination of high-index sapphire optics and a 1,024-element detector array. Special hardware and software automatically compensate for temperature in readings over a wide temperature range.

The ultimate choice for DEF testing.

Misco’s digital refractometer is the ideal instrument for testing DEF to prevent the use of fluid that is outside expected values. MISCO refractometers meet or exceed the requirements of ASTM D7821 – 12, Standard Test Method for Field Determination of Urea Concentration in Diesel Exhaust Fluid (DEF).


The American Petroleum Institute (API), a non-profit industry organization and advocate for the oil and natural gas industry, is charged with certifying manufacturers of Diesel Exhaust Fluid (DEF) for selective catalytic reduction (SCR) equipped diesel engines in North America. The best way to guarantee good DEF fluid is to only purchase urea bearing API certification and frequently test the fluid with a MISCO refractometer to ensure it meets quality requirements.

A refractometer can tell if it gives less environmental impact; it’s definitely DEF.

Options include; additional scales to measure urea density, specific gravity, and freezing point. As well as, engine coolant concentration and freezing point, brake fluid moisture content or boiling point, and windshield washer fluid. There is also a rubber armored jacket (in three different colors) and a virtually indestructible storage case.

PDF (3)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *