Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frost
Item number 10-MFM300-KIT4

Multi-Function Instrument Deluxe Kit 4

Call for price

In stock

Lightweight and versatile, the MFM300 expands your capabilities. It’s your choice… use the following instruments and tools: digital thermometers, anemometers, sling psychrometers, data loggers, meters, P-T and psychrometric charts, or simply use one… the MFM300. The MFM300 has the ability to measure, calculate, and display the following: Temperature – 3 zones, Delta T, Min-, max- and average values, pressure, superheat and subcooling, psychrometrics, airflow, data logging, and it is upgradable. The MFM300 is designed as a modular, upgradable, and expandable system that allows the user to add probes, functions, and features as needed. Eliminates cost!

Documents:mfm300
Request a quote 10-MFM300-KIT4
  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Description
Features
Hard carrying case
model 5400 vane CFM Thermo-Anemometer
model 5029 humidity sensor
model 5200 1000 PSI pressure sensor
Hard case strap
maximizes the capacity of MFM300 Kit 1 to 3
model 5250 500 PSI pressure sensor
model 4011 surface sensor with 8″ Velcro strap
model 1075 puncture sensor
model MFM300 Multifunctional Contact Expandable Instrument
MFM300 Kit4 – Deluxe Kit – includes:
Temperature range 58 °F to 302 °F ( -5 °C to 150 °C )
Temperature accuracy ±0.3 °F ( ±0.2 °C )
or ±0.5% of Reading (whichever is greater)
Ambient temperature 32 °F to 122 °F ( 0 °C to 50 °C )
Resolution Temperature: 0.1° Relative Humidity: 1% Pressure: 1 psi (1 kPa)
Airflow: 1fpm ( 0.001 m/s )
LCD height Character height: 0.15 inch ( 3.8 mm ) 8 lines w/ 20 characters per line (up to 160 characters.
Housing, material Housing: impact-resistant plastic protective Boot: SBS
Sensor type Temperature
Relative humidity (cold medium)
Airflow
Response time Display refresh rate: 1/sec.
Shaft length Probe 1075: 4.101 Mm) 5029 probe: 5.127 Mm) 4011, 5400, 5200 & 5250: N/A
Shaft diameter 1075 Probe: 0.140 in. (3.5 Mm) 5029 sensor: 0.25 in. (6.4 Mm)
4011, 5400, 5200 & 5250:N/A
Cable length Probe 1075: 6 meters. (1.8M) coiled cord 4011 probe: 12 meters. (3.66M)
5029, 5400, 5200 & 5250:6 Meters. (1.8 M)
Cable jacket Polyurethane
Battery life 100 Hours Minimum
Weight 1 lb. (Not including the sensors.
Dimensions Length: 7.75 in. (197 Mm) Width: 4 in. (100 Mm) Depth: 1.5 in. (38 Mm)
Specification
Features
Hard carrying case
model 5400 vane CFM Thermo-Anemometer
model 5029 humidity sensor
model 5200 1000 PSI pressure sensor
Hard case strap
maximizes the capacity of MFM300 Kit 1 to 3
model 5250 500 PSI pressure sensor
model 4011 surface sensor with 8″ Velcro strap
model 1075 puncture sensor
model MFM300 Multifunctional Contact Expandable Instrument
MFM300 Kit4 – Deluxe Kit – includes:
Temperature range 58 °F to 302 °F ( -5 °C to 150 °C )
Temperature accuracy ±0.3 °F ( ±0.2 °C )
or ±0.5% of Reading (whichever is greater)
Ambient temperature 32 °F to 122 °F ( 0 °C to 50 °C )
Resolution Temperature: 0.1° Relative Humidity: 1% Pressure: 1 psi (1 kPa)
Airflow: 1fpm ( 0.001 m/s )
LCD height Character height: 0.15 inch ( 3.8 mm ) 8 lines w/ 20 characters per line (up to 160 characters.
Housing, material Housing: impact-resistant plastic protective Boot: SBS
Sensor type Temperature
Relative humidity (cold medium)
Airflow
Response time Display refresh rate: 1/sec.
Shaft length Probe 1075: 4.101 Mm) 5029 probe: 5.127 Mm) 4011, 5400, 5200 & 5250: N/A
Shaft diameter 1075 Probe: 0.140 in. (3.5 Mm) 5029 sensor: 0.25 in. (6.4 Mm)
4011, 5400, 5200 & 5250:N/A
Cable length Probe 1075: 6 meters. (1.8M) coiled cord 4011 probe: 12 meters. (3.66M)
5029, 5400, 5200 & 5250:6 Meters. (1.8 M)
Cable jacket Polyurethane
Battery life 100 Hours Minimum
Weight 1 lb. (Not including the sensors.
Dimensions Length: 7.75 in. (197 Mm) Width: 4 in. (100 Mm) Depth: 1.5 in. (38 Mm)
PDF (1)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *