Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseThree seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseThree seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screen
Item number 10-MFM300-KIT1

Multi-function Instrument Panel Air Conditioning Set 1

Call for price

In stock

Lighten the load and expand your capabilities with the MFM300. It’s your choice… use the following instruments and tools: Digital thermometers, anemometers, sling psychrometers, dataloggers, meters, P-T and psychrometric charts, or simply use one… the MFM300. The MFM300 has the ability to measure, calculate, and display the following: Temperature – 3 zones, Delta T, Min-, max- and average values, pressure, superheat and subcooling, psychrometrics, airflow, datalogging, and is upgradable. The MFM300 is designed as a modular, upgradable, and expandable system that allows the user to add probes, functions, and features as needed. Eliminates the cost!

Documents:mfm300
Request a quote 10-MFM300-KIT1
  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Description
Features
Model 5029 humidity sensor
Hard case strap
Perform basic air balancing
Model 4011 surface sensor with 8″ Velcro strap
Hard carrying case
Model MFM300 Multifunction Connector Expandable Instrument
Model 1075 piercing sensor
Model 5400 Vane CFM Thermo-Anemometer
Verify system efficiency
Displays instantaneous psychrometrics
Temperature Range 58 °F to 302 °F ( -5 °C to 150 °C )
Temperature Accuracy ±0.3 °F ( ±0.2 °C )
or ±0.5% of Reading (whichever is greater)
Ambient Temperature 32 °F to 122 °F ( 0 °C to 50 °C )
Resolution Temperature: 0.1 °
Relative Humidity: 1%
Pressure: 1 psi (1 kPa)
Airflow: 1 fpm ( 0.001 m/s )
LCD Height Character height: 0.15 inches ( 3.8 mm )
8 Lines with 20 characters per line (up to 160 characters.
Housing, Material Housing: impact-resistant plastic
Protective Boot: SBS
Sensor Type Temperature
Relative Humidity
(Refrigerant)
Airflow
Response time Display update rate: 1/sec.
Shaft length 1075 Probe:4. 101 MM)
5029 Probe:5. 127 MM)
4011 Probe:N/A
5400 Probe:N/A
Shaft diameter 1075 Probe:0,140 I. (3,5 Mm)
5029 Probe:0.25 In. (6,4 Mm)
4011 Probe:N/A
5400 Probe:N/A
Cable length 1075 Probe:6 Meter. (1.8M) coiled cable
4011 Probe:12 Meter. (3.66M)
5400 &Amp; 5029 probes:6 Meter. (1,8 M)
Cable jacket Polyurethane
Battery life 100 Hours Minimum
Weight 1 lb. (Not including probes.
Dimensions Length: 7,75 i. ( 197 Mm )
Width: 4. (100 MM)
Depth: 1,5 i. ( 38 Mm )
Specification
Features
Model 5029 humidity sensor
Hard case strap
Perform basic air balancing
Model 4011 surface sensor with 8″ Velcro strap
Hard carrying case
Model MFM300 Multifunction Connector Expandable Instrument
Model 1075 piercing sensor
Model 5400 Vane CFM Thermo-Anemometer
Verify system efficiency
Displays instantaneous psychrometrics
Temperature Range 58 °F to 302 °F ( -5 °C to 150 °C )
Temperature Accuracy ±0.3 °F ( ±0.2 °C )
or ±0.5% of Reading (whichever is greater)
Ambient Temperature 32 °F to 122 °F ( 0 °C to 50 °C )
Resolution Temperature: 0.1 °
Relative Humidity: 1%
Pressure: 1 psi (1 kPa)
Airflow: 1 fpm ( 0.001 m/s )
LCD Height Character height: 0.15 inches ( 3.8 mm )
8 Lines with 20 characters per line (up to 160 characters.
Housing, Material Housing: impact-resistant plastic
Protective Boot: SBS
Sensor Type Temperature
Relative Humidity
(Refrigerant)
Airflow
Response time Display update rate: 1/sec.
Shaft length 1075 Probe:4. 101 MM)
5029 Probe:5. 127 MM)
4011 Probe:N/A
5400 Probe:N/A
Shaft diameter 1075 Probe:0,140 I. (3,5 Mm)
5029 Probe:0.25 In. (6,4 Mm)
4011 Probe:N/A
5400 Probe:N/A
Cable length 1075 Probe:6 Meter. (1.8M) coiled cable
4011 Probe:12 Meter. (3.66M)
5400 &Amp; 5029 probes:6 Meter. (1,8 M)
Cable jacket Polyurethane
Battery life 100 Hours Minimum
Weight 1 lb. (Not including probes.
Dimensions Length: 7,75 i. ( 197 Mm )
Width: 4. (100 MM)
Depth: 1,5 i. ( 38 Mm )
PDF (1)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *