Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleGhost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseThree seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleGhost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseThree seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how long
Item number 53-CG104

Coating Thickness Gauge with Eddy Current and Magnetic Induction

3.914 SEK

In stock
Request a quote 53-CG104

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category:

Description

Features

  • Eddy current and magnetic induction measure ferrous (iron and steel) and non-ferrous (copper, aluminum, zinc, brass, etc.) substrates
  • Magnetic induction for iron
  • Eddy current measurement for non-ferrous metal substrates
  • Easy to use
  • 180° flip LCD display with backlight
  • Saves/recalls up to 255 measurements
  • Audio alarm for high/low alarm limits
  • Zero adjustment and two-point calibration
  • Records/Stores Min/max/average readings
  • Auto-freezes the reading on the display
  • Automatic power-off and low battery indicator
  • Complete with two AAA batteries, calibration standards (one ferrous plate, one non-ferrous plate, and one standard coated film plate), wrist strap, and soft case

AC Measurement CG104 Coating Thickness Tester Extech’s CG104 offers fast, one-handed, non-destructive measurement of the thickness of ferrous and non-ferrous substrates. Its unique flip screen allows you to take readings in challenging angles of the area being measured.

Applications:

  • Paint thickness on cars
  • Quality control and monitoring of anodizing or hot-dip galvanizing
  • Suitable for paint manufacturers, painters, and anti-corrosion contractors
  • Tool machine manufacturers, pipeline, and aviation industry
Specification

Features

  • Eddy current and magnetic induction measure ferrous (iron and steel) and non-ferrous (copper, aluminum, zinc, brass, etc.) substrates
  • Magnetic induction for iron
  • Eddy current measurement for non-ferrous metal substrates
  • Easy to use
  • 180° flip LCD display with backlight
  • Saves/recalls up to 255 measurements
  • Audio alarm for high/low alarm limits
  • Zero adjustment and two-point calibration
  • Records/Stores Min/max/average readings
  • Auto-freezes the reading on the display
  • Automatic power-off and low battery indicator
  • Complete with two AAA batteries, calibration standards (one ferrous plate, one non-ferrous plate, and one standard coated film plate), wrist strap, and soft case

AC Measurement CG104 Coating Thickness Tester Extech’s CG104 offers fast, one-handed, non-destructive measurement of the thickness of ferrous and non-ferrous substrates. Its unique flip screen allows you to take readings in challenging angles of the area being measured.

Applications:

  • Paint thickness on cars
  • Quality control and monitoring of anodizing or hot-dip galvanizing
  • Suitable for paint manufacturers, painters, and anti-corrosion contractors
  • Tool machine manufacturers, pipeline, and aviation industry