Palm Abbe Digital Refractometer for Seawater: Salinity, Density, Specific Gravity, Conductivity & Chlorination
6.993 SEK
The Palm Abbe AQUAR Digital seawater refractometer is a professional refractometer for testing seawater, saltwater, and brackish water for oceanography, aquaculture, aquariums, desalination plants, and ocean research. The AQUAR-H5O model measures seawater salinity in practical salinity units (PSU), Sigma-t density, specific gravity, conductivity, and Chlorinity.
Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%
- Free shipping on orders over 3000 SEK excl. VAT
- Measuring instruments and gauges for professionals
- Call us +46 8 753 00 04
Description
52-PA203X-058-173-175-178-180
52-PA203X-058-173-175-178-180
| Scale | Medium | Unit of Measure | Display Shows | Measuring Range | Resolution | Precision |
|---|---|---|---|---|---|---|
| 058 | Seawater | Specific Gravity (D20/20) | SeaW D 20/20 | 1.0000 to 1.1180 | 0.0001 | 0.0005 |
| 173 | Seawater | Practical Salinity Units (PSU) | Seawater PSU | 0 to 155 | 1 | 1 |
| 175 | Seawater | Density Sigma/t @ 20°C | Sigma-t 20°C | -2 to 116 | 0.1 | 0.5 |
| 178 | Seawater | Conductivity @ 20 °C (mS/cm) | MS/cm @ 20°C | 0 to 100 | 0.1 | 0.5 |
| 180 | Seawater | Chlorinity (ppt) | SeaW Cl ppt | 0 to 85.5 | 0.1 | 0.5 |
From sea to land, the AQUAR seawater refractometer measures salinity in seawater, salt water, & brackish water
Get accurate measurements of seawater salinity, density, specific gravity, conductivity, and chlorinity!
Misco’s AQUAR™ Digital seawater refractometer is at home on board a ship or on the beach, and is specifically designed for oceanography, aquaculture, professional aquariums, desalination plants, and ocean research.
This refractometer can overcome many of the limitations of other testing methods, including chloride titration, specific gravity with a hydrometer, and conductivity meters for testing seawater, salt water, and brackish water.
The AQUAR series of refractometers is based on the established physical properties of seawater and the latest scientific research, as published by the United Nations Educational, Scientific and Cultural Organization (UNESCO) and others.
It is this seawater foundation that distinguishes the MISCO AQUAR REFRACTOMETER from other refractometers based solely on common salt and water. Although sodium chloride is one of the most important components in seawater, there are numerous other components that make a standard sodium chloride refractometer inaccurate with regard to the physical properties of seawater. Other refractometers, which claim to be seawater refractometers, are likely based on outdated data and display results in ppt instead of the accepted practical salinity units.
Traditional analog refractometers display the reading at the point where a shadow line crosses a small glass dot reticle. Many of these refractometers are not automatically temperature-compensated, meaning that the reading can be significantly affected for every degree Celsius the instrument’s temperature varies from 20 °C (68 °F). Furthermore, readings on analog refractometers are subjective and difficult to read on a boat pitching on the water’s surface.
Misco’s AQUAR seawater refractometer series offers the most stable and accurate digital handheld refractometers. With a precision of ± 0.0005 specific gravity, the AQUAR rivals many benchtop laboratory instruments that cost thousands of dollars more.
Measuring seawater on the Palm Abbe is quick and efficient. The instrument can be zeroed to fresh water and makes exactly repeatable measurements in the blink of an eye. Place a seawater sample in the measuring area, close the evaporation cover, and press the GO button. The automatically temperature-compensated reading is displayed on the large 24-character display in seconds. The user can browse and select an appropriate scale (unit) by pressing the MENU button. Calibration to water is automatic and requires no screws or manual adjustments.
Although the AQUAR H2O and AQUAR H5O base models have special preset scales, up to five customized seawater measurement units can be programmed into a Palm Abbe PA203X for a truly customized instrument. The user can choose from a number of physical properties including, salinity, expressed in practical salinity units (PSU), specific gravity and density at a number of reference temperatures, sigma-t, conductivity, Freezing points and chlorinity. Call for more information.
Specification
52-PA203X-058-173-175-178-180
52-PA203X-058-173-175-178-180
| Scale | Medium | Unit of Measure | Display Shows | Measuring Range | Resolution | Precision |
|---|---|---|---|---|---|---|
| 058 | Seawater | Specific Gravity (D20/20) | SeaW D 20/20 | 1.0000 to 1.1180 | 0.0001 | 0.0005 |
| 173 | Seawater | Practical Salinity Units (PSU) | Seawater PSU | 0 to 155 | 1 | 1 |
| 175 | Seawater | Density Sigma/t @ 20°C | Sigma-t 20°C | -2 to 116 | 0.1 | 0.5 |
| 178 | Seawater | Conductivity @ 20 °C (mS/cm) | MS/cm @ 20°C | 0 to 100 | 0.1 | 0.5 |
| 180 | Seawater | Chlorinity (ppt) | SeaW Cl ppt | 0 to 85.5 | 0.1 | 0.5 |
From sea to land, the AQUAR seawater refractometer measures salinity in seawater, salt water, & brackish water
Get accurate measurements of seawater salinity, density, specific gravity, conductivity, and chlorinity!
Misco’s AQUAR™ Digital seawater refractometer is at home on board a ship or on the beach, and is specifically designed for oceanography, aquaculture, professional aquariums, desalination plants, and ocean research.
This refractometer can overcome many of the limitations of other testing methods, including chloride titration, specific gravity with a hydrometer, and conductivity meters for testing seawater, salt water, and brackish water.
The AQUAR series of refractometers is based on the established physical properties of seawater and the latest scientific research, as published by the United Nations Educational, Scientific and Cultural Organization (UNESCO) and others.
It is this seawater foundation that distinguishes the MISCO AQUAR REFRACTOMETER from other refractometers based solely on common salt and water. Although sodium chloride is one of the most important components in seawater, there are numerous other components that make a standard sodium chloride refractometer inaccurate with regard to the physical properties of seawater. Other refractometers, which claim to be seawater refractometers, are likely based on outdated data and display results in ppt instead of the accepted practical salinity units.
Traditional analog refractometers display the reading at the point where a shadow line crosses a small glass dot reticle. Many of these refractometers are not automatically temperature-compensated, meaning that the reading can be significantly affected for every degree Celsius the instrument’s temperature varies from 20 °C (68 °F). Furthermore, readings on analog refractometers are subjective and difficult to read on a boat pitching on the water’s surface.
Misco’s AQUAR seawater refractometer series offers the most stable and accurate digital handheld refractometers. With a precision of ± 0.0005 specific gravity, the AQUAR rivals many benchtop laboratory instruments that cost thousands of dollars more.
Measuring seawater on the Palm Abbe is quick and efficient. The instrument can be zeroed to fresh water and makes exactly repeatable measurements in the blink of an eye. Place a seawater sample in the measuring area, close the evaporation cover, and press the GO button. The automatically temperature-compensated reading is displayed on the large 24-character display in seconds. The user can browse and select an appropriate scale (unit) by pressing the MENU button. Calibration to water is automatic and requires no screws or manual adjustments.
Although the AQUAR H2O and AQUAR H5O base models have special preset scales, up to five customized seawater measurement units can be programmed into a Palm Abbe PA203X for a truly customized instrument. The user can choose from a number of physical properties including, salinity, expressed in practical salinity units (PSU), specific gravity and density at a number of reference temperatures, sigma-t, conductivity, Freezing points and chlorinity. Call for more information.






There are no reviews yet.