Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleGhost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseThree seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The Cold Room Stopped Cooling Overnight – Get the Alarm Before the Goods Are RuinedThe bearing sounded fine on Thursday and failed on Monday: how logged vibration values make wear visibleGhost voltage that disappears when the meter loads the circuit: how to tell real voltage from falseThree seconds and the right viewing angle: how temperature checks actually get doneWhy a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how long
Item number 56-TB-3040SI

TandD Thermal Buffer Mount (10-pack) — dampens temperature variations around the probe, e.g., for refrigeration/freezer monitoring

3.912 SEK

In stock

TandD Thermal Buffer Mount (10-pack) — dampens temperature variations around the probe, e.g., for refrigeration/freezer monitoring

Request a quote 56-TB-3040SI

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category: , , , , , , ,

Other models in the series 16

Description

The 56-TB-3040SI is a thermal buffer mount — an aluminum block in which the probe is placed to simulate thermal mass. This results in more stable readings, as intermittent disturbances (brief drafts, opening a cold room door, short-term solar exposure) have less impact on the measurement. Selected for refrigeration/freezer monitoring where you want to see the ”true” temperatures of stored goods, rather than temporary air fluctuations. Supplied in a 10-pack.