Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Vernier Caliper Shows a Different Depth Every Time and What a Depth Micrometer Does DifferentlyA bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frost
Item number 56-RTR503B

TandD Wireless Logger for Temperature and Humidity with External T/RH Sensor. 0–55 °C, 10–95 %RH. Range up to 150 m, Bluetooth

2.911 SEK

In stock

TandD Wireless logger for temperature and humidity with external T/RH sensor. 0–55 °C, 10–95 %RH. Range up to 150 m, Bluetooth

Request a quote 56-RTR503B

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category: , , ,

Other models in the series 16

Description

The 56-RTR503B is TandD’s standard logger for combined temperature and humidity measurement with an external T/RH probe on cable — perfect when you need to measure at a specific point (wine bottle, pharmaceutical packaging, plant pot, warehouse shelf) while the logger unit with radio sits safely at a distance. The measuring range of 0–55 °C and 10–95 %RH covers most indoor environments.

The TR-3310 probe is included as standard. Measurement data is transmitted wirelessly via radio (EU: 869.7–870 MHz) to any RTR-500B base unit at a direct line-of-sight distance of up to 150 meters, or longer with a repeater. For higher precision and a wider measuring range, see the 56-RTR507B (with SHA-3151 high-precision probe).

Features

  • External T/RH probe on cable (TR-3310 included)
  • Temperature measuring range: 0 to +55 °C
  • Humidity measuring range: 10 to 95 %RH
  • Accuracy temperature: ±0.5 °C / Humidity: ±5 %RH (at 25 °C, 50 %RH)
  • Resolution 0.1 °C / 1 %RH
  • Wireless range approx. 150 meters line-of-sight
  • 8,000 data point memory (one data point = both temperature + RH)
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • Battery life approx. 10 months on LS14250
  • Built-in LCD displays current values (alternating temp/RH) and battery warning
  • Bluetooth 4.2 BLE for configuration via mobile app

Specification

Measurement channels Temperature 1 channel (thermistor) + Humidity 1 channel (polymer) — external, on cable
Measuring range 0 to +55 °C / 10 to 95 %RH
Accuracy ±0.5 °C / ±5 %RH (at 25 °C, 50 %RH)
Resolution 0.1 °C / 1 %RH
Response time (90 %) approx. 7 minutes
Logging capacity 8,000 data points (combined temp + RH)
Logging mode Endless or One Time
Wireless communication EU: 869.7–870 MHz, RF power 5 mW, range approx. 150 m
Other interfaces Bluetooth 4.2 BLE, optical communication
Protection class IP64 on the logger unit (T/RH probe is not water-resistant)
Power supply Lithium battery LS14250 × 1 (included)
Battery life approx. 10 months
Dimensions 62 × 47 × 19 mm (excl. protruding parts and probe)
Weight approx. 50 g
Operating environment -40 to +80 °C (during wireless transmission: -30 to +80 °C)
Compatible base units 56-RTR500BC, 56-RTR500BW, 56-RTR500BM

Included accessories

  • 56-RTR503B logger
  • External T/RH probe 56-TR-3310
  • 1 × Lithium battery LS14250
  • Strap for hanging
  • Manual set with warranty certificate

Applications

The 56-RTR503B is selected for daily T/RH monitoring needs in indoor environments: food storage, wine cellars, greenhouses, museums and archives, pharmaceutical warehouses, classrooms, offices, and data centers where both temperature and humidity are critical. For higher accuracy (±2.5 %RH) and a wider measuring range (-25 to 70 °C), choose the 56-RTR507B. For a compact built-in probe without cable, see the 56-RTR32B (Bluetooth).

Additional information
Product Type

Measures

% Relative Humidity, Temperature

Communication

Wireless Bluetooth, Wireless Long Range