Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readingsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A bore can hold size at one point and still be both tapered and ovalThe temperature was right when the load was loaded, but what happened during transport?With a 0.4-second temperature reading, you can measure accurately before the product has had time to changeCore temperature is what counts: how to document cooling and heating processes without handwritten listsThe cold chain failed overnight, but nobody can prove when or for how longUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors RemoveFrom ”it looks like a crack” to a measured and documented dimension on screenAntifreeze protection in the cooling system can look right and still be wrong: how to measure glycol content and freezing point in secondsHow to know that the glycol in your cooling circuit actually protects against frostTemperature and humidity in the warehouse can be monitored without anyone going there to take readings
Item number 56-RTR502B

TandD Wireless Temperature Logger with External Probe on Cable. Measuring Range -60 to +155 °C Depending on Probe. Range Up to 150 m, Bluetooth

1.973 SEK

In stock

TandD Wireless temperature logger with external probe on cable. Measuring range -60 to +155 °C depending on probe. Range up to 150 m, Bluetooth

Request a quote 56-RTR502B

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and gauges for professionals
  • Call us +46 8 753 00 04

Category: , , ,

Other models in the series 16

Description

The 56-RTR502B is TandD’s versatile temperature logger featuring a probe on a cable separate from the electronics — place the logger in a reasonably accessible location and insert the probe where the temperature actually needs to be measured: in the freezer, in the oven, in the thermal container, in the cooling circuit, or simply in tight spaces. The measuring range extends from -60 to +155 °C depending on the probe used, covering everything from deep freezing to industrial hot processes.

The standard kit includes thermistor probe 56-TR-5106. If you require higher or lower temperatures, different cable lengths, or IP-rated applications — choose from TandD’s wide selection of compatible external probes (56-TR-1106 waterproof, 56-TR-1220/1320 for IT/food, 56-TR-3100 series for special applications, among others). Measurement data is transmitted wirelessly to any RTR-500B base unit at a direct line-of-sight distance of up to 150 meters.

Features

  • External thermistor probe on cable — flexible placement, easy to replace
  • Measuring range -60 to +155 °C (depending on selected probe)
  • Fast response time: approx. 80 sec in air, approx. 7 sec in stirred water
  • Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C (-40 to -20 °C, 80 to 110 °C), ±1.0 °C (-60 to -40 °C, 110 to 155 °C)
  • IP64 splash protection on the logger unit itself (the probe is not water-resistant as standard)
  • Wireless range approx. 150 meters line-of-sight
  • 16,000 data point memory (Endless mode)
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • Battery life approx. 10 months on LS14250 lithium cell
  • Built-in LCD displays current temperature and battery warning
  • Bluetooth 4.2 BLE for configuration via mobile app

Specification

Measurement channel Temperature 1 channel — thermistor (external, on cable)
Measuring range -60 to +155 °C (depending on probe)
Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C (-40 to -20 °C, 80 to 110 °C), ±1.0 °C (-60 to -40 °C, 110 to 155 °C)
Resolution 0.1 °C
Response time (90 %) approx. 80 sec in air / approx. 7 sec in stirred water
Logging capacity 16,000 data points
Logging mode Endless or One Time
Wireless communication EU: 869.7–870 MHz, RF power 5 mW, range approx. 150 m
Other interfaces Bluetooth 4.2 BLE, optical communication
Protection class IP64 on logger (daily splash protection)
Power supply Lithium battery LS14250 × 1 (included)
Battery life approx. 10 months
Dimensions 62 × 47 × 19 mm (excl. protruding parts and probe) — antenna length 24 mm
Weight approx. 50 g
Operating environment -40 to +80 °C (during wireless transmission: -30 to +80 °C)
Compatible base units 56-RTR500BC, 56-RTR500BW, 56-RTR500BM

Included

  • 56-RTR502B logger
  • External thermistor probe 56-TR-5106 (standard probe for the logger)
  • 1 × Lithium battery LS14250
  • Strap for hanging
  • Manual set with warranty certificate

Options

  • 56-RTR-500B1 — Large battery compartment for longer operating time (convert to L-model)
  • 56-AT-50K1 — Wall mount
  • 56-TR-1C30, 56-TR-2C30, 56-TR-3C30 — Extension cables for probes (3 m)
  • Alternative probes: 56-TR-1106 (waterproof), 56-TR-1220/1320, 56-TR-3100 series — contact us for the right choice

Applications

The 56-RTR502B is selected when you need to measure temperatures outside the -40/+80 °C range or when you need to place the electronics in a safe location while the probe is positioned directly at the measurement point. Typical applications: ovens and baking ovens, freezers (refrigeration and freezing equipment), hot water circuits, industrial heating and cooling systems, autoclaves, refrigerated holds on ships, and storage dryers. For a simpler integrated temperature logger without an external probe, see 56-RTR501B. For combined temperature + humidity, see 56-RTR503B.

Additional information
Product Type

Measures

Temperature

Communication

Wireless Bluetooth, Wireless Long Range